The use of medical devices containing highly criticized phthalates including di(2-ethylhexyl) phthalate (DEHP) has been challenged by European directive 2007/47/CE, put into effect in March 2010. New plasticizers are now being used to soften PVC in medical devices: trioctyltrimellitate (TOTM), di-isononyl-cyclohexan-1,2-dicarboxilate (DINCH) and di(2-ethylhexyl) terephthalate (DEHT). To quantify DEHP in nine DEHP-free medical devices made of PVC softened by alternative plasticizers, high performance liquid chromatography analysis with ultraviolet detection at 220 nm wavelength was achieved. An NMR spectroscopy was performed to confirm DEHP presence. Only two medical devices out of the nine tested were truly without DEHP. One of them showed traces of DEHP exceeding the threshold contamination of 0.1% in plastic mass set by REACH regulations. TOTM plasticizer is still incriminated when polyvinyl-chloride (PVC) is contaminated with DEHP. Manufacturers must verify the purity of their raw material, not only on PVC, but also on other soft plastics entering into the composition of medical infusion devices. The clinical consequences of exposure to certain levels of DEHP have not been evaluated. A solution could be to use alternative PVC-free materials.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijpharm.2011.03.060 | DOI Listing |
J Family Med Prim Care
December 2024
Department of Neonatology, All India Institute of Medical Science, Jodhpur, Rajasthan, India.
Context: Heart rate (HR) is the most vital parameter to assess hemodynamic transition at birth. ECG is considered a gold standard for HR assessment. New devices with dry electrodes are easy to apply on a wet newborn.
View Article and Find Full Text PDFJ Family Med Prim Care
December 2024
Department of Community Medicine, Medical College, Kolkata, West Bengal, India.
Introduction: India is committed to achieving universal health care for all by 2030. The objective of social marketing is to promote public health and its goal is to improve health for all, but there are some challenges like irregular availability, quality issue, inadequacy of marketing causes under- utilization of the government supplied health consumables.
Objectives: Present study aims to find out the usage pattern and assess the perceived satisfaction level of beneficiaries of using various socially marketed health consumables at government settings and explore the perception of healthcare personnel regarding barriers to its usage in a rural area of India.
Ann Thorac Surg Short Rep
December 2024
Children's Heart Institute, Children's Memorial Hermann Hospital, University of Texas Health Science Center at Houston McGovern Medical School, Houston, TX, USA.
"Swiss-cheese" ventricular septal defects present complex treatment challenges. Despite difficult defect visualization and closure, complete septation is the treatment of choice. We present the case of a 2-year-old with residual apical "Swiss-cheese" ventricular septal defects after failed percutaneous device closure with 2 occluder devices.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Duke University Medical Center, Durham, North Carolina.
Background: Direct mechanical ventricular actuation (DMVA) with the Anstadt cup is effective for non-blood-contacting biventricular support. Pneumatic regulation of a silicone device augments ventricular pump function. Vacuum attachment facilitates diastolic augmentation critical for biventricular support.
View Article and Find Full Text PDFCardiovasc Diagn Ther
December 2024
Department of Cardiology, Tokai University School of Medicine, Isehara, Japan.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!