The maze procedure is the gold standard for the ablation of atrial fibrillation, and the "box lesion" around the pulmonary veins is the most important part of this procedure. We have created this lesion with a bipolar radiofrequency ablator, abandoning the usual use of this device (to achieve bilateral epicardial isolation of the pulmonary veins).From March 2004 through the end of May 2010, we performed surgical ablation of atrial fibrillation in 240 patients. Of this number, 205 underwent operation by a hybrid maze technique and the remaining 35 (our study cohort) underwent the creation of a box lesion around the pulmonary veins by means of a bipolar radiofrequency device. Ablation lines were created by connecting the left atriotomy to the amputated left atrial appendage, with 2 ablation lines made with a bipolar radiofrequency device above and below the pulmonary veins. Lesions were made along the transverse and oblique sinuses by epicardial and endocardial application of a bipolar device. The left atrial isthmus was ablated by bipolar radiofrequency and cryoprobe. No complications were associated with the box lesion: 90% and 89% of patients were in sinus rhythm at 3 and 6 months of follow-up, respectively.By creating a box lesion around the pulmonary veins, we expect to improve transmurality by means of epicardial and endocardial ablation of 1 rather than 2 layers of atrial wall, as in epicardial pulmonary vein isolation. Isolation of the entire posterior wall of the left atrium is better electrophysiologically and renders dissection around the pulmonary veins unnecessary.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3066805 | PMC |
Indian Pacing Electrophysiol J
January 2025
Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA. Electronic address:
J Clin Med
January 2025
Gastroenterology and Digestive Endoscopy Unit, Forlì-Cesena Hospitals, 47121 Romagna, Italy.
Endoscopic ultrasound (EUS)-guided radiofrequency ablation (RFA) is a promising minimally invasive technique for the treatment of pancreatic lesions. This review first focuses on the technical aspects in EUS-RFA: the procedure typically employs EUS probes with integrated radiofrequency electrodes, enabling accurate targeting and ablation of pancreatic lesions. Different types of RFA devices, monopolar and bipolar energy delivery systems, are discussed, along with considerations for optimal ablation, including energy settings, procedure time, and pre- and post-procedural management.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
January 2025
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN (T.H., M.E.R., O.Y., G.N.K., N.O., T.K., L.N., D.L.P., K.C.S.).
Background: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
January 2025
Department of Cardiovascular Medicine, Dokkyo Medical University, 880 Kitakobayashi, Mibu, Shimotsugagun, Tochigi, 321-0293, Japan.
Background: The conventional mapping approach for the atrioventricular accessory pathway (AP) involves point-by-point mapping to identify the connection sites of the AP to the atria or ventricle and accurate interpretation of local electrograms. Omnipolar mapping technology (OMT) explains how vector and wave speed are produced by using both unipolar and bipolar signals to obtain omnipolar signals, directions, and conduction velocity. The aim of this study is to verify the effectiveness of OMT for catheter ablation of AP.
View Article and Find Full Text PDFEpilepsia
January 2025
Academic Center for Epileptology (ACE), Kempenhaeghe/Maastricht UMC+, Maastricht & Heeze, Maastricht, The Netherlands.
Objective: To investigate whether local lesions created by stereo-electroencephalography (SEEG)-guided radiofrequency thermocoagulation (RFTC) affect distant brain connectivity and excitability in patients with focal, drug-resistant epilepsy (DRE).
Methods: Ten patients with focal DRE underwent SEEG implantation and subsequently 1 Hz bipolar repetitive electrical stimulation (RES) for 30 s before and after RFTC. Root mean square (RMS) of cortico-cortical evoked potentials (CCEPs) was calculated for 15 ms to 300 ms post-stimulation with baseline correction.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!