Objectives: To determine the impact of the harmonic scalpel on intraoperative blood loss and operative time in selective neck dissection (SND) (levels I-IV) for head and neck squamous cell carcinoma (HNSCC).
Study Design: Prospective randomized controlled trial.
Setting: A single, tertiary care institution (Foothills Medical Centre) in Calgary, Alberta, Canada.
Subjects: A total of 31 patients (36 neck dissections) were prospectively enrolled between January 2009 and March 2010.
Methods: Patients were randomized to receive a neck dissection with either the harmonic scalpel or the traditional technique of using electrocautery and sharp dissection. The study included adult patients older than age 18 years diagnosed with HNSCC and who required an SND (levels I-IV). Study exclusion criteria included previous treatment for head and neck cancer and all patients unwilling or unable to provide informed consent. Primary clinical outcomes were intraoperative blood loss and operative time. Secondary outcomes included intraoperative complications and surgical drain output.
Results: Intraoperative blood loss was significantly lower in the harmonic scalpel group compared to the traditional group (158 vs 61 mL, P = .02). There was no difference in operative time (81 minutes harmonic vs 85 minutes traditional) or total drain output (at both 48 hours and 1 week) between the groups. There were no intraoperative complications reported in either group.
Conclusions: Results from this study suggest that the harmonic scalpel can reduce blood loss during SND for HNSCC. The harmonic scalpel had no impact on operative time, postoperative drain output, or complication rate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0194599811403874 | DOI Listing |
Int J Surg
December 2024
Department of Surgery, Sapienza University of Rome, Rome.
Background: One of the most important surgical steps during thyroidectomy is the safe ligation of vessels. In fact, it is crucial to avoid postoperative bleeding and nerves' injury. The "clamp and tie" technique was first introduced in the 19th century.
View Article and Find Full Text PDFSurg Innov
January 2025
Department of Otolaryngology - Head & Neck Surgery, Kirk Kerkorian School of Medicine at UNLV, Las Vegas, NV, USA.
Objective: The Thunderbeat (TB) is a new surgical device that combines ultrasonic and bipolar energy. The objective of this study is to examine how the combined ultrasonic and bipolar shears affect surgical outcomes when compared to other methods.
Data Sources And Review Methods: Using the PRISMA guidelines, the researchers used broad search terms in PubMed, Embase, and Web of Science, which produced a total of 2823 initial results, with years ranging from 1955 to June 2024.
Int J Surg
October 2024
Department of Surgery, Sapienza University of Rome, Rome, Italy.
Background: One of the most important surgical steps during thyroidectomy is the safe ligation of vessels. In fact, it is crucial to avoid postoperative bleeding and nerves' injury. The "clamp and tie" technique was first introduced in the 19th century.
View Article and Find Full Text PDFBMC Surg
December 2024
Intern, Department of Medical Rehabilitation, UniOsun Teaching Hospital, Osogbo, Nigeria.
Background: Seroma has been associated with some energy devices used in raising flaps during modified radical mastectomy. Perhaps, its occurrence might be reduced by determining the most effective technique for raising the flap. Hence, the wide array of energy devices available for mastectomy warrants a network meta-analysis for comparison to determine the most suitable for rseducing complications.
View Article and Find Full Text PDFJ Thorac Dis
November 2024
Department of Cardiac Surgery, Peking University Third Hospital, Beijing, China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!