Estimation of accuracy of patient-specific musculoskeletal modelling: case study on a post polio residual paralysis subject.

Comput Methods Biomech Biomed Engin

UTC CNRS UMR 6600, Biomécanique et Bioingénierie (BMBI), Université de Technologie de Compiègne (UTC), BP 20529, 60205, Compiègne Cedex, France.

Published: October 2012

For patients with patterns ranging out of anthropometric standard values, patient-specific musculoskeletal modelling becomes crucial for clinical diagnosis and follow-up. However, patient-specific modelling using imaging techniques and motion capture systems is mainly subject to experimental errors. The aim of this study was to quantify these experimental errors when performing a patient-specific musculoskeletal model. CT scan data were used to personalise the geometrical model and its inertial properties for a post polio residual paralysis subject. After having performed a gait-based experimental protocol, kinematics data were measured using a VICON motion capture system with six infrared cameras. The musculoskeletal model was computed using a direct/inverse algorithm (LifeMod software). A first source of errors was identified in the segmentation procedure in relation to the calculation of personalised inertial parameters. The second source of errors was subject related, as it depended on the reproducibility of performing the same type of gait. The impact of kinematics, kinetics and muscle forces resulting from the musculoskeletal modelling was quantified using relative errors and the absolute root mean square error. Concerning the segmentation procedure, we found that the kinematics results were not sensitive to the errors (relative error<1%). However, a strong influence was noted on the kinetics results (deviation up to 71%). Furthermore, the reproducibility error showed a significant influence (relative mean error varying from 5 to 30%). The present paper demonstrates that in patient-specific musculoskeletal modelling variations due to experimental errors derived from imaging techniques and motion capture need to be both identified and quantified. Therefore, the paper can be used as a guideline.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10255842.2011.558086DOI Listing

Publication Analysis

Top Keywords

patient-specific musculoskeletal
12
musculoskeletal modelling
12
post polio
8
polio residual
8
residual paralysis
8
paralysis subject
8
motion capture
8
experimental errors
8
musculoskeletal model
8
source errors
8

Similar Publications

The Masquelet technique that combines a foreign body reaction (FBR)-induced vascularized tissue membrane with staged bone grafting for reconstruction of segmental bone defect has gained wide attention in Orthopedic surgery. The success of Masquelet hinges on its ability to promote formation of a "periosteum-like" FBR-induced membrane at the bone defect site. Inspired by Masquelet's technique, here a novel approach is devised to create periosteum mimetics from decellularized extracellular matrix (dECM), engineered in vivo through FBR, for reconstruction of segmental bone defects.

View Article and Find Full Text PDF

Introduction: Musculoskeletal pain is the second leading cause of disease burden in Australia, and there is a need to investigate new models of care to cope with the increasing demand for health services. This paper describes the protocol for a randomised controlled trial investigating whether a physiotherapist-led triage and treatment service is non-inferior for improving function at 6 months and superior for reducing treatment waiting times, compared with usual care for patients with musculoskeletal pain referred to public hospital outpatient physiotherapy clinics.

Methods And Analysis: A total of 368 participants (184 per arm) will be recruited from six public hospitals located in metropolitan Sydney, Australia.

View Article and Find Full Text PDF

Design, characterisation, and clinical evaluation of a novel porous Ti-6Al-4V hemipelvic prosthesis based on Voronoi diagram.

Biomater Transl

September 2024

Orthopaedic Research Institute and Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China.

Three-dimensional printed Ti-6Al-4V hemipelvic prosthesis has become a current popular method for pelvic defect reconstruction. This paper presents a novel biomimetic hemipelvic prosthesis design that utilises patient-specific anatomical data in conjunction with the Voronoi diagram algorithm. Unlike traditional design methods that rely on fixed, homogeneous unit cell, the Voronoi diagram enables to create imitation of trabecular structure (ITS).

View Article and Find Full Text PDF

Introduction: Achilles tendon rupture is the most commonly ruptured tendon in humans. Recent evidence suggests no significant differences in long-term functional outcomes between conservative and surgical management. Conservative treatment carries a higher risk of re-rupture, while surgical management presents risks such as wound infections and sural nerve damage.

View Article and Find Full Text PDF

Completeness of repeated patient-reported outcome measures in adult rehabilitation: a randomized controlled trial in a diverse clinical population.

BMC Health Serv Res

December 2024

Health Services Research and Innovation Unit, and Center for Treatment of Rheumatic and Musculoskeletal Diseases (REMEDY), Diakonhjemmet Hospital, Oslo, Norway.

Background: Data collection through patient-reported outcome measures (PROMs) is essential for the purpose of rehabilitation research and registries. Existing problems with incomplete PROM data may relate to the patient burden and data set length. This study aimed to analyse response patterns and degree of data completeness in systematic outcome assessments conducted within a clinical study in a multidisciplinary rehabilitation setting, comparing completeness of a brief and a longer set of PROMs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!