Purpose: The optimal management of a nerve gap within the fingers remains an unanswered question in hand surgery. The purpose of this study was to compare the sensory recovery, cost, and complication profile of digital nerve repair using autogenous vein and polyglycolic acid conduits.

Methods: We enrolled patients undergoing repair of digital nerve injuries with gaps precluding primary repair. The minimum gap that was found to preclude primary repair was 4 mm. Each nerve repair was randomized to the type of nerve repair with either a woven polyglycolic acid conduit or autogenous vein. Time required for repair was recorded. We performed sensory testing, consisting of static and moving 2-point discrimination, at 6 and 12 months after repair. We compared patient factors between the 2 groups using chi-square and Student's t-test. We compared sensory recovery between the 2 groups at each time point using Student's t-test and compared time and cost of repair.

Results: We enrolled 42 patients with 76 nerve repairs. Of these, 37 patients (representing 68 repairs) underwent sensory evaluation at the 6-month time point. The median age in this group was 35 years. We repaired 36 nerves with synthetic conduit and 32 with vein. Nerve gaps ranged from 4 to 25 mm (mean, 10 mm). Study groups were not significantly different regarding age, time to repair, gap length, medical history, smoking history, or worker's compensation status. Time to harvest the vein was longer but the average cost of materials and surgery in the vein group was $1,220, compared with $1,269 for synthetic conduit repairs. These differences were not statistically significant. Mean static and moving 2-point discrimination at 6 months for the synthetic conduit group were 8.3 ± 2.0 and 6.6 ± 2.3, respectively, compared with 8.5 ± 1.8 and 7.1 ± 2.2 for the vein group. Values at 12 months for the synthetic conduit group were 7.5 ± 1.9 and 5.6 ± 2.2, compared with 7.6 ± 2.6 and 6.6 ± 2.9 for the vein group. These differences were not statistically significant. Smokers and worker's compensation patients had a worse sensory recovery at 12 months postrepair. There were 2 extrusions in the synthetic conduit group requiring reoperation; however, the difference in extrusion rate was not found to be statistically significant.

Conclusions: Sensory recovery after digital nerve reconstruction with autogenous vein conduit was equivalent to that using polyglycolic acid conduit, with a similar cost profile and fewer postoperative complications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2011.01.030DOI Listing

Publication Analysis

Top Keywords

synthetic conduit
20
polyglycolic acid
16
autogenous vein
16
digital nerve
16
sensory recovery
16
nerve repair
12
vein group
12
conduit group
12
vein
9
nerve
9

Similar Publications

Amputated neuromas, a common consequence of peripheral nerve injury, can cause significant pain and may impair daily life. Herein, we conducted a retrospective study on patients who underwent a nerve-capping technique using the bioabsorbable nerve conduit Renerve®, with a minimum follow-up period of 6 months. We conducted a retrospective study to assess patients with amputation neuromas of the finger or palm who underwent surgical treatment using the capping technique with the Renerve® conduit between October 2018 and September 2022.

View Article and Find Full Text PDF

The combination of macroporous cryogels with synthetic peptide factors represents a promising but poorly explored strategy for the development of extracellular matrix (ECM)-mimicking scaffolds for peripheral nerve (PN) repair. In this study, IKVAV peptide was functionalized with terminal lysine residues to allow its in situ cross-linking with gelatin macromer, resulting in the formation of IKVAV-containing proteinaceous cryogels. The controllable inclusion and distribution of the peptide molecules within the scaffold was verified using a fluorescently labelled peptide counterpart.

View Article and Find Full Text PDF

Purpose: The management of parastomal hernia following cystectomy and ileal conduit diversion is challenging due to its specific nature and a high recurrence rate, yet is poorly described.

Methods: We retrospectively searched the clinical data warehouse of our center for patients who had primary parastomal hernia repair following cystectomy and ileal conduit diversion. The primary endpoint was recurrence of parastomal hernia; secondary endpoints were postoperative complications and surgical management of recurrences.

View Article and Find Full Text PDF

Synthetic vascular grafts are promising conduits for small caliber arteries. However, due to restenosis caused by intimal hyperplasia, they cannot keep long patency in vivo. In this work, through single cell RNA sequencing, we found that thrombospondin-1 (THBS1) was highly expressed in the regenerated smooth muscle cells (SMCs) in electrospun polycaprolactone (PCL) vascular grafts.

View Article and Find Full Text PDF

Artificial ionic nanochannels with light perception capabilities hold promise for creating ionic devices. Nevertheless, most research primarily focuses on regulating single nanochannels, leaving the cumulative effect of numerous nanochannels and their integration underexplored. We herein develop a biomimetic photoreceptor based on photoresponsive highly aligned nanochannels (pHANCs), which exhibit uniform channel heights, phototunable surface properties, and excellent compatibility with microfabrication techniques, enabling the scalable fabrication and integration into functional ionic devices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!