AI Article Synopsis

Article Abstract

Objective: The purpose of our study was to evaluate the influence of epidural anesthesia on the hearing system in women undergoing normal labor.

Design: We examined two groups of patients: women with epidural anesthesia underwent four tests of distortion product otoacoustic emissions(DPOAEs): on admission, and fifteen minutes, one hour, and three hours after the last epidural bolus of local anesthetic. Auditory brainstem response (ABR) tests were performed on admission, and one hour, and three hours after the last epidural bolus. Women who gave birth without epidural anesthesia underwent DPOAEs tests on admission, during a uterine contraction, during active delivery, and three hours after labor. ABR tests were performed on admission, during a uterine contraction, and three hours after labor.

Study Sample: twenty patients participated in the study. Twelve gave birth with epidural anesthesia and eight without anesthesia.

Results: No significant changes in DPOAEs and ABR recordings were found between the two groups.

Conclusions: Epidural anesthesia does not impair the sensory or the neural elements of the hearing system and therefore does not influence hearing.

Download full-text PDF

Source
http://dx.doi.org/10.3109/14992027.2011.568012DOI Listing

Publication Analysis

Top Keywords

epidural anesthesia
24
three hours
16
hearing system
12
influence epidural
8
anesthesia hearing
8
anesthesia underwent
8
hour three
8
hours epidural
8
epidural bolus
8
abr tests
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!