Electromechanically assisted gait training is a promising task-oriented approach for gait restoration, especially for people with subacute stroke. However, few guidelines are available for selecting the parameter values of the electromechanical Gait Trainer (GT) (Reha-Stim; Berlin, Germany) and none is tailored to a patient's motor capacity. We assessed 342 GT sessions performed by 20 people with stroke who were stratified by Functional Ambulatory Category. In the first GT session of all patients, the body-weight support (BWS) required was higher than that reported in the literature. In further sessions, we noted a slow reduction of BWS and a fast increment of walking speed for the most-affected patients. Inverse trends were observed for the less-affected patients. In all the patients, the heart rate increment was about 20 beats per minute, even for sessions in which the number of strides performed was up to 500. In addition, the effective BWS measured during GT sessions was different from that initially selected by the physiotherapist. This difference depended mainly on the position of the GT platforms during selection. Finally, harness acceleration in the anteroposterior direction proved to be higher in patients with stroke than in nondisabled subjects. Our findings are an initial step toward scientifically selecting parameters in electromechanically assisted gait training.

Download full-text PDF

Source
http://dx.doi.org/10.1682/jrrd.2010.04.0069DOI Listing

Publication Analysis

Top Keywords

electromechanically assisted
12
assisted gait
12
gait trainer
8
people stroke
8
gait training
8
gait
5
patients
5
driving electromechanically
4
trainer people
4
stroke
4

Similar Publications

Background: Imaging both electrical and mechanical cardiac function can better characterize cardiac disease and improve patient care. Currently, there is no noninvasive technique that can simultaneously image both electrical and mechanical function of the whole heart at the point of care. Here, our aim is to demonstrate that high volume-rate echocardiography can simultaneously map cardiac electromechanical activation and end-systolic cardiac strain of the whole heart in a single heartbeat.

View Article and Find Full Text PDF

Wearable nanocomposite stretch sensors are an exciting new development in biomaterials for biomechanical motion-tracking technology, with applications in the treatment of low back pain, knee rehabilitation, fetal movement tracking, and other fields. When strained, the resistance of the low-cost sensors is reduced, enabling human motion to be monitored using a suitable sensor array. However, current sensor technologies have exhibited significant drift, in the form of increased electrical resistance, if left stored in typical room conditions.

View Article and Find Full Text PDF

Shaping the ear cartilage and preserving the shape are important and quite difficult. The aim of this study was to demonstrate the effectiveness of the Wharton's jelly-derived stem cell-assisted electromechanical reshaping method in a rabbit ear cartilage defect model and to compare it with surgical reshaping.For the purpose of 25 × 4-mm cartilage defect reconstruction, 48 rabbit ears were divided into 2 main groups according to the shaping method, and these main groups were divided into 3 subgroups according to stem cell injection: control, sham, and stem cell.

View Article and Find Full Text PDF
Article Synopsis
  • * Atrial fibrillation is marked by irregular heart activity that leads to changes in the atrial structure and function, while celiac disease results from an immune response causing intestinal damage linked to specific genetic mutations.
  • * The findings suggest a potential association between AF and CD due to inflammation and fibrosis, highlighting the need for awareness of AF risks in CD patients and the importance of integrated patient care, with more research needed to clarify their relationship and discover treatment options.
View Article and Find Full Text PDF

The remarkable properties of magnetic nanostructures have sparked considerable interest within the biomedical domain, owing to their potential for diverse applications. In targeted drug delivery systems, therapeutic molecules can be loaded onto magnetic nanocarriers and precisely guided and released within the body with the assistance of an externally applied magnetic field. However, conventional external magnetic fields generated by permanent magnets or electromagnets are limited by finite magnetic field gradients, shallow penetration depths, and low precision.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!