In electromagnetic dosimetry, anatomical human models are commonly obtained by segmentation of magnetic resonance imaging or computed tomography scans. In this paper, a human head model extracted from thermal infrared images is examined in terms of its applicability to specific absorption rate (SAR) calculations. Since thermal scans are two-dimensional (2D) representation of surface temperature, this allows researchers to overcome the extensive computational demand associated with 3D simulation. The numerical calculations are performed using the finite-difference time-domain method with mesh sizes of 2 mm at 900 MHz plane wave irradiation. The power density of the incident plane wave is assumed to be 10 W/m(2). Computations were compared with a realistic anatomical head model. The results show that although there were marked differences in the local SAR distribution in the various tissues in the two models, the 1 g peak SAR values are approximately similar in the two models.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10255842.2011.563738DOI Listing

Publication Analysis

Top Keywords

extracted thermal
8
thermal infrared
8
infrared images
8
head model
8
plane wave
8
head models
4
models extracted
4
images dosimetry
4
dosimetry computations
4
computations electromagnetic
4