A parallel microfluidic flow cytometer for high-content screening.

Nat Methods

Boston University, Department of Biomedical Engineering, Boston, Massachusetts, USA.

Published: May 2011

A parallel microfluidic cytometer (PMC) uses a high-speed scanning photomultiplier-based detector to combine low-pixel-count, one-dimensional imaging with flow cytometry. The 384 parallel flow channels of the PMC decouple count rate from signal-to-noise ratio. Using six-pixel one-dimensional images, we investigated protein localization in a yeast model for human protein misfolding diseases and demonstrated the feasibility of a nuclear-translocation assay in Chinese hamster ovary (CHO) cells expressing an NFκB-EGFP reporter.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3084896PMC
http://dx.doi.org/10.1038/nmeth.1595DOI Listing

Publication Analysis

Top Keywords

parallel microfluidic
8
microfluidic flow
4
flow cytometer
4
cytometer high-content
4
high-content screening
4
screening parallel
4
microfluidic cytometer
4
cytometer pmc
4
pmc high-speed
4
high-speed scanning
4

Similar Publications

A single microfluidic device for multi-omics analysis sample preparation.

Lab Chip

January 2025

Spectrométrie de Masse Biologique et Protéomique SMBP, ESPCI Paris, LPC CNRS UMR 8249, PSL University, 10 Rue Vauquelin, F-75005 Paris, France.

Combining different "omics" approaches, such as genomics and proteomics, is necessary to generate a detailed and complete insight into microbiome comprehension. Proper sample collection and processing and accurate analytical methods are crucial in generating reliable data. We previously developed the ChipFilter device for proteomic analysis of microbial samples.

View Article and Find Full Text PDF

Plasmids play a vital role in synthetic biology by enabling the introduction and expression of foreign genes in various organisms, thereby facilitating the construction of biological circuits and pathways within and between cell populations. For many applications, maintaining functional plasmids without antibiotic selection is critical. This study introduces an open-hardware-based microfluidic workflow for analyzing plasmid retention by culturing single cells in gel microdroplets and quantifying microcolonies using fluorescence microscopy.

View Article and Find Full Text PDF

Superfast nanodroplet propulsion in 2D nanochannels tuned by strain gradients.

Nanoscale

January 2025

Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, School of Mechanical Engineering, Southeast University, Nanjing, 211189, China.

Directional transport of droplets is crucial for industrial applications and chemical engineering processes, with significant potential demonstrated in water harvesting, microfluidics, and heat transfer. In this work, we present a novel approach to induce self-driving behavior in nanodroplets within a two-dimensional (2D) nanochannel using a strain gradient, as demonstrated through molecular dynamics simulations. Our findings reveal that a small strain gradient imposed along a nanochannel constructed by parallel surfaces can induce water transport at ultrafast velocities (O(10 m s)), far exceeding macroscale predictions.

View Article and Find Full Text PDF

Highly parallel simulation tool for the design of isotachophoresis experiments.

Anal Chim Acta

February 2025

Department of Mechanical Engineering, Stanford University, 488 Escondido Mall, Stanford, CA, 94305, USA. Electronic address:

Background: Isotachophoresis (ITP) is a well-established electrokinetic method for separation and preconcentration of analytes. Several simulation tools for ITP have been published, but their use for experimental design is limited by the computational time for a single run and/or by the number of conditions that can be investigated per simulation run. A large fraction of the existing solvers also do not account for ionic strength effects, which can influence whether an analyte focuses in ITP.

View Article and Find Full Text PDF

Modeling of Electric Field and Dielectrophoretic Force in a Parallel-Plate Cell Separation Device with an Electrode Lid and Analytical Formulation Using Fourier Series.

Sensors (Basel)

December 2024

Department of Applied Physics, National Defense Academy, Hashirimizu 1-10-20, Yokosuka 239-0802, Kanagawa, Japan.

Dielectrophoresis (DEP) cell separation technology is an effective means of separating target cells which are only marginally present in a wide variety of cells. To develop highly efficient cell separation devices, detailed analysis of the nonuniform electric field's intensity distribution within the device is needed, as it affects separation performance. Here we analytically expressed the distributions of the electric field and DEP force in a parallel-plate cell separation DEP device by employing electrostatic analysis through the Fourier series method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!