To develop agents for radionuclide imaging Aβ plaques in vivo, we prepared three fluorine-substituted analogs of arylbenzothiazole class; compound 2 has a high affinity for Aβ (K(i)=5.5nM) and the specific binding to Aβ in fluorescent staining. In preparation for the synthesis of these arylbenzothiazole analogs in radiolabeled form as an Aβ plaques-specific positron emission tomography (PET) imaging probe, we investigated synthetic route suitable for its labeling with the short-lived PET radionuclide fluorine-18 (t(1/2)=110min) and diaryliodonium tosylate precursors (12, 13a-e and 14). 2-Aryl-6-[(18)F]fluorobenzothiazoles ([(18)F]1-3) were synthesized in efficiently short reaction times (40-60min) with high radiochemical yields (19-40%), purities (>95%) and specific activities (85-118GBq/μmol). Tissue distribution studies showed that high radioactivity of [(18)F]2 accumulated in the brain with rapid clearance in healthy mice. Radioactive metabolites were analyzed in brain samples of mice and corresponded to 81% of parent remained by 30min after a tail-vein injection. These results suggest that [(18)F]2 is a promising probe for evaluation of Aβ plaques imaging in brain using PET.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bmc.2011.03.029DOI Listing

Publication Analysis

Top Keywords

positron emission
8
emission tomography
8
imaging probe
8
aβ plaques
8
5
aromatic radiofluorination
4
radiofluorination biological
4
biological evaluation
4
evaluation 2-aryl-6-[18f]fluorobenzothiazoles
4
2-aryl-6-[18f]fluorobenzothiazoles potential
4

Similar Publications

18F-Sodium Fluoride PET/CT as a Tool to Assess Enthesopathies in X-Linked Hypophosphatemia.

Calcif Tissue Int

January 2025

Endocrinology Department, School of Medicine, Pontificia Universidad Católica de Chile, Av. Diagonal Paraguay 262, Cuarto Piso, Santiago, Chile.

X-linked hypophosphatemia (XLH) is a rare metabolic disorder characterized by elevated FGF23 and chronic hypophosphatemia, leading to impaired skeletal mineralization and enthesopathies that are associated with pain, stiffness, and diminished quality of life. The natural history of enthesopathies in XLH remains poorly defined, partly due to absence of a sensitive quantitative tool for assessment and monitoring. This study investigates the utility of 18F-NaF PET/CT scans in characterizing enthesopathies in XLH subjects.

View Article and Find Full Text PDF

Background: Mycobacterium avium complex (MAC) is a common pathogen causing non-tuberculous mycobacterial infections, primarily affecting the lungs. Disseminated MAC disease occurs mainly in immunocompromised individuals, such as those with acquired immunodeficiency syndrome, hematological malignancies, or those positive for anti-interferon-γ antibodies. However, its occurrence in solid organ transplant recipients is uncommon.

View Article and Find Full Text PDF

Clinical and biochemical factors associated with amygdalar metabolic activity.

NPJ Aging

January 2025

Division of Cardiovascular Medicine, Department of Medicine, Kurume University School of Medicine, 67 Asahi-machi, Kurume, Japan.

We investigated clinical factors and biochemical markers associated with amygdalar metabolic activity evaluated by [F]-fluorodeoxyglucose-positron emission tomography (FDG-PET) in 346 subjects without a history of malignant neoplasms. Univariate regression analysis revealed significant relationships between amygdalar metabolic activity and fasting plasma glucose (FPG), glycated hemoglobin, coronary artery disease (CAD) history, aspirin use, oral hypoglycemic agents (OHAs) use, and asymmetric dimethylarginine (ADMA). In multiple stepwise regression analysis, FPG and CAD history were independently associated with amygdalar metabolic activity.

View Article and Find Full Text PDF

Quantitative and Visual Benefits of Data-Driven Motion Correction on Oncologic PET/CT: A Prospective Cross-sectional Study.

Acad Radiol

January 2025

Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, St. Louis, MO 63110 (S.I., M.A.T., M.I., C.S., R.L., A.H., R.L.W., T.J.F.). Electronic address:

Rationale And Objective: Conventional positron emission tomography (PET) respiratory gating utilizes a fraction of acquired PET counts (i.e., optimal gate [OG]), whereas elastic motion correction with deblurring (EMCD) utilizes all PET counts to reconstruct motion-corrected images without increasing image noise.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!