This study aims to monitor retention of a single ingested lead shot in young mallards, and to evaluate effect on growth in relation to lead shot size class during late wing growth and the first wing molt period (8 to 12 weeks old). Toxicological tests, radiography and biometric measurements were conducted on 51 juvenile Mallard ducks. Forty one of them were given per os a single lead shot in three different commercially available sizes: No. 2 (LS2), No. 4 (LS4) and No. 6 (LS6). Less than 20% of total lead shots were found on X-rays at Day 21 (D) and none remained at D28, with mean retention time in gizzard calculated 12.85±1.34 days for all treated groups. Young ducks developed high blood lead levels for each LS treatment at D15 in males and females, the maximal values being for LS2 (297.00±78.64 μg/100 mL and 483.14±83.70 μg/100 mL, respectively (p<0.001)). Zinc protoporphyrin (ZPP) levels increased at D15 with LS2 and LS4 in males and only with LS6 in females. Treated ducks developed no symptoms of plumbism except light diarrhea, and at D40, all mallards had survived. We found that LS2 pellets released more lead in gizzards and produced the highest levels of blood lead, suggesting that LS2 pellets are more likely to intoxicate mallards than smaller sizes. The biometric measurements performed showed no statistical difference in weight or bill and wing length between control and treated groups, a finding suggesting that absorption of a single lead shot by young Mallard ducks does not affect their development during the first wing molt period, and appears not to compromise the flight capacity of young (post-juvenile) mallards. However, younger mallards and/or effects on growth of exposure to more than a single-shot dose still need to be investigated.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.scitotenv.2011.03.012 | DOI Listing |
Forensic Sci Int
December 2024
Ballistics Section of the Spanish Scientific Police Headquarters (National Police), Julián González Segador s/n, Madrid, Spain; Instituto Universitario de Investigación en Ciencias Policiales (IUICP), Universidad de Alcalá, Alcalá de Henares, Madrid, Spain.
Firearm-related scenarios can be highly complex, involving multiple shooters, firearms, types of ammunition, victims, and various impact zones. Obtaining the maximum amount of information to connect each piece of the puzzle is crucial for resolving these cases. Currently, new tools are being developed in the forensic field that facilitate both fieldwork and laboratory analysis, enabling the estimation of trajectories, identification of shooters, and more.
View Article and Find Full Text PDFIntroduction: Pulsed field ablation (PFA) is a form of nonthermal energy that has been recently introduced for pulmonary vein isolation (PVI). A multi-electrode pentaspline catheter for delivery of PFA guided by fluoroscopy has become widely available for clinical use.
Methods And Results: In this study, we aimed to assess whether the addition of electroanatomical mapping (EAM) for confirmation of PVI in the acute phase can increase the efficacy of the procedure in terms of arrhythmia recurrences.
Sci Rep
December 2024
Orthopedics Department, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, 100020, China.
Diabetes foot ulcer (DFU) is one of the common complications of diabetes patients, which may lead to infection, necrosis and even amputation. Therefore, early diagnosis, classification of severity and related treatment are crucial for the patients. Current DFU classification methods often require experienced doctors to manually classify the severity, which is time-consuming and low accuracy.
View Article and Find Full Text PDFMethods Enzymol
November 2024
Diamond Light Source Ltd, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom; Rosalind Franklin Institute, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom.
This chapter describes additions to the DIALS software package for processing serial still-shot crystallographic data, and the implementation of a pipeline, xia2.ssx, for processing and merging serial crystallography data using DIALS programs. To integrate partial still-shot diffraction data, a 3D gaussian profile model was developed that can describe anisotropic spot shapes.
View Article and Find Full Text PDFSensors (Basel)
October 2024
School of Automation, Central South University, Changsha 410083, China.
In few-shot fault diagnosis tasks in which the effective label samples are scarce, the existing semi-supervised learning (SSL)-based methods have obtained impressive results. However, in industry, some low-quality label samples are hidden in the collected dataset, which can cause a serious shift in model training and lead to the performance of SSL-based method degradation. To address this issue, the latest prototypical network-based SSL techniques are studied.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!