Background: A remote magnetic navigation (MN) system is available for radiofrequency ablation of atrial fibrillation (AF), challenging the conventional manual ablation technique. The myocardial markers were measured to compare the effects of the two types of MN catheters with those of a manual-irrigated catheter in AF ablation.

Methods: AF patients underwent an ablation procedure using either a conventional manual-irrigated catheter (CIR, n = 65) or an MN system utilizing either an irrigated (RMI, n = 23) or non-irrigated catheter (RMN, n = 26). Levels of troponin T (TnT) and the cardiac isoform of creatin kinase (CKMB) were measured before and after ablation.

Results: Mean procedure times and total ablation times were longer employing the remote magnetic system. In all groups, there were pronounced increases in markers of myocardial injury after ablation, demonstrating a significant correlation between total ablation time and post-ablation levels of TnT and CKMB (CIR r = 0.61 and 0.53, p < 0.001; RMI r = 0.74 and 0.73, p < 0.001; and RMN r = 0.51 and 0.59, p < 0.01). Time-corrected release of TnT was significantly higher in the CIR group than in the other groups. Of the patients, 59.6% were free from AF at follow-up (12.2 ± 5.4 months) and there were no differences in success rate between the three groups.

Conclusions: Remote magnetic catheters may create more discrete and predictable ablation lesions measured by myocardial enzymes and may require longer total ablation time to reach the procedural endpoints. Remote magnetic non-irrigated catheters do not appear to be inferior to magnetic irrigated catheters in terms of myocardial enzyme release and clinical outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3184221PMC
http://dx.doi.org/10.1007/s10840-011-9567-zDOI Listing

Publication Analysis

Top Keywords

remote magnetic
12
ablation atrial
8
atrial fibrillation
8
manual-irrigated catheter
8
total ablation
8
ablation
7
magnetic versus
4
versus manual
4
manual catheters
4
catheters evaluation
4

Similar Publications

Remote ischemic conditioning (RIC) has attracted considerable attention as a brain protection strategy, although its impact remains unclear. Hypothermia is the most effective strategy in experimental transient cerebral ischemia. Therefore, we compared the efficacy of RIC, hypothermia, and no treatment on cerebral ischemia.

View Article and Find Full Text PDF

Ligand Inter-Relation Analysis Via Graph Theory Predicts Macrophage Response.

Adv Mater

December 2024

Department of Materials Science and Engineering, Korea University, Seoul, 02841, Republic of Korea.

Graph theory has been widely used to quantitatively analyze complex networks of molecules, materials, and cells. Analyzing the dynamic complex structure of extracellular matrix can predict cell-material interactions but has not yet been demonstrated. In this study, graph theory-based mathematical modeling of RGD ligand graph inter-relation is demonstrated by differentially cutting off RGD-to-RGD interlinkages with flexibly conjugated magnetic nanobars (MNBs) with tunable aspect ratio.

View Article and Find Full Text PDF

The native extracellular matrix is continuously remodeled to form complex interconnected network structures that reversibly regulate stem cell behaviors. Both regulation and understanding of its intricate dynamicity can help to modulate numerous cell behaviors. However, neither of these has yet been achieved due to the lack of designing and modeling such complex structures with dynamic controllability.

View Article and Find Full Text PDF

Introduction: The treatment of early onset scoliosis (EOS) has seen significant advancements, particularly with the introduction of magnetically controlled growing rods (MCGR). However, a discrepancy between reported and actual rod lengthening during treatment has raised concerns.

Hypothesis: This retrospective study aims to investigate the disparity between reported and actual lengthening of MCGR and to identify factors contributing to the failure of the lengthening process.

View Article and Find Full Text PDF

A complete workflow from embalmed specimens to life-like 3D virtual models for veterinary anatomy teaching.

J Anat

December 2024

Department of Veterinary Anatomy, Physiology and Pathology, Institute of Infection, Veterinary and Ecological Sciences, University of Liverpool, Liverpool, UK.

Understanding normal structural and functional anatomy is critical for health professionals across various fields such as medicine, veterinary, and dental courses. The landscape of anatomical education has evolved tremendously due to several challenges and advancements in blended learning approaches, which have led to the adoption of the use of high-fidelity 3D digital models in anatomical education. Cost-effective methods such as photogrammetry, which creates digital 3D models from aligning 2D photographs, provide a viable alternative to expensive imaging techniques (i.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!