A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Five-year comparison of oxidized zirconium and cobalt-chromium femoral components in total knee arthroplasty: a randomized controlled trial. | LitMetric

Background: In vitro analysis has shown that oxidized zirconium on ultra-high molecular weight polyethylene has better wear properties than cobalt-chromium on ultra-high molecular weight polyethylene. The purpose of this study was to determine if oxidized zirconium femoral components performed better than cobalt-chromium in vivo and if the use of oxidized zirconium components had clinical adverse effects.

Methods: Forty consecutive patients (eighty knees) underwent simultaneous bilateral cruciate-retaining total knee arthroplasty for primary osteoarthritis from January 2002 to December 2003. For each patient, the knees were randomized to receive the oxidized zirconium femoral component, with the contralateral knee receiving the cobalt-chromium component. Outcome measures included the Western Ontario and McMaster Universities Osteoarthritis Index, Knee Injury and Osteoarthritis Outcome Score, Knee Society score, and British Orthopaedic Association patient satisfaction scale. Radiographic outcomes include the Knee Society total knee arthroplasty roentgenographic evaluation and scoring system and measurement of radiographic wear. Patients and assessors were blinded to the treatment groups and results.

Results: There were no significant differences in clinical, subjective, and radiographic outcomes between the two implants at five days, six weeks, and one, two, or five years postoperatively. At five years following surgery, 38% of the patients preferred the cobalt-chromium knee compared with 18% who preferred the oxidized zirconium knee (p = 0.02) and 44% had no preference.

Conclusions: Five-year outcomes after total knee arthroplasty with oxidized zirconium and cobalt-chromium femoral components showed no significant differences in clinical, subjective, and radiographic outcomes. Patients had no preference or preferred the cobalt-chromium prosthesis to the oxidized zirconium prosthesis at the time of the five-year follow-up. There were no adverse effects associated with the use of oxidized zirconium femoral implants.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.I.01753DOI Listing

Publication Analysis

Top Keywords

oxidized zirconium
36
total knee
16
knee arthroplasty
16
femoral components
12
zirconium femoral
12
radiographic outcomes
12
knee
10
oxidized
9
zirconium
9
zirconium cobalt-chromium
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!