The number of patients on oral anticoagulant therapy has increased in recent years, and this trend is expected to continue. The increased workload for physicians has led to the development of computerized systems to make organizational workflow more efficient. These programs may include algorithms to propose a weekly dosage and timing for the following visit. Before introducing a new algorithm in clinical practice, its safety and efficacy must be validated. We undertook a retrospective simulation study to test a new algorithm for the TAOnet system. The main outcome was the percentage of concordant and discordant proposals between manual- and algorithm-based prescriptions. Pairs of computerized and physician prescriptions were assessed. They were categorized as 0.1-5, 5.1-10 and >10% if the dose was different, and assigned as "algorithm better" or "manual better" dependent upon the subsequent international normalized ratio value. In 61.0% of cases, the manual and computerized weekly dosage assignments were identical; in 15.3% of cases, the difference was between 0.1 and 5%; in 14.7 of cases, it was between 5.1 and 10%; and in 9.0% of cases, it was >10%. The algorithm did better in 43.9% of discordant pairs, generally due to less frequent under-dosing. In conclusion, the new algorithm proved to consistently overlap with the manual method. The algorithm is useful but must be tested in a multi-center, prospective, interventional study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11739-011-0581-z | DOI Listing |
J Cancer Res Clin Oncol
January 2025
Department of Medical Oncology, Cancer Center, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, Sichuan, 610041, China.
Purpose: To evaluate the added value of additional Ga-FAPI PET/CT following CT for primary staging, detection of postoperative recurrence, and management of gastric cancer patients.
Methods: We retrospectively included patients with gastric cancers who underwent contrast-enhanced computed tomography (ceCT), followed by Ga-FAPI PET/CT within 30 days. Ga-FAPI PET/CT was performed for initial staging or detection of postoperative recurrence.
Atherosclerosis
December 2024
Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust, London, UK; Centre for Cardiovascular Medicine and Devices, William Harvey Research Institute, Queen Mary University of London, London, UK. Electronic address:
Background And Aims: Coronary angiography-derived wall shear stress (WSS) may enable identification of vulnerable plaques and patients. A new recently introduced software allows seamless three-dimensional quantitative coronary angiography (3D-QCA) reconstruction and WSS computation within a single user-friendly platform carrying promise for clinical applications. This study examines for the first time the efficacy of this software in detecting vulnerable lesions in patients with intermediate non-flow limiting stenoses.
View Article and Find Full Text PDFJ Med Internet Res
January 2025
Hospital Administration, Ramaiah Memorial Hospital, Bengaluru, Karnataka, India.
Background: Monitoring vital signs in hospitalized patients is crucial for evaluating their clinical condition. While early warning scores like the modified early warning score (MEWS) are typically calculated 3 to 4 times daily through spot checks, they might not promptly identify early deterioration. Leveraging technologies that provide continuous monitoring of vital signs, combined with an early warning system, has the potential to identify clinical deterioration sooner.
View Article and Find Full Text PDFJ Am Acad Orthop Surg
September 2024
From the Department of Orthopaedic Surgery, Keck Medical Center of the University of Southern California, Los Angeles, CA (Ihn, Chung, Lovro, Patterson, Christ, and Heckmann), the Department of Orthopaedic Surgery, Mayo Clinic, Rochester, MN (Chen), the Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA (Tucker), and the Department of Radiology, Keck Medical Center of the University of Southern California, Los Angeles, CA (White, and Hwang).
Introduction: Vascular injury during acetabular screw fixation is a life-threatening complication of total hip arthroplasty. This study uses three-dimensional computed tomography to (1) measure absolute distance from the external iliac artery (EIA) to the acetabulum, (2) determine available bone stock along the EIA path, and (3) create a novel acetabular vascular risk map.
Methods: A retrospective radiographic study was conducted using three-dimensional CT.
Radiol Phys Technol
January 2025
Department of Radiotherapy, Sri Shankara Cancer Hospital and Research Centre, 1st Cross, Shankarapuram, Basavanagui, Bengaluru, 560004, Karnataka, India.
This study evaluates the dosimetric impact of arc simulation angular resolution in VMAT-based Single Isocentre Multiple Target (SIMT) SRS, focusing on their dependence on target size, isocentre distance, number of arcs, and arc type. A phantom study analysed angular resolution (0.5°, 1°, 2°) effects on dosimetric accuracy for PTVs of 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!