A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A computer-controlled olfactometer for a self-administered odor identification test. | LitMetric

A computer-controlled olfactometer for a self-administered odor identification test.

Eur Arch Otorhinolaryngol

Department of Otorhinolaryngology, Interdisciplinary Center for Smell and Taste Research, University of Dresden Medical School, Dresden, Germany.

Published: September 2011

Odor identification tests are widely used for the general screening of olfactory function. However, the administration of odor identification tests is often limited due to a lack of investigators' time. Therefore, we attempted to design a computer-controlled olfactometer to present a self-administered odor identification test. The results produced by means of this olfactometer were evaluated in terms of validity and test-retest reliability. To test the validity, participants' performance in the odor identification test using the olfactometer was compared with their performance in the odor identification test using the validated assessment of the "Sniffin' Sticks" test. The ten-item odor identification test was performed two times using two different methods: (1) the self-administered test using the computer-controlled olfactometer and (2) the foreign-administered test using the "Sniffin' sticks." To examine test-retest reliability, 20 participants were asked to repeat these tests on a different day. Participants reached significantly higher scores on a foreign-administered odor identification test using the "Sniffin' sticks" than on the olfactometer-based test; however, this effect was driven by two less correctly identified odors in the olfactometer-based test. The significant difference between both methods in the mean scores disappeared after excluding two odors from the analysis. In addition, both methods showed no significant difference in scores obtained during the first and second session, indicating that results were consistent between sessions. In conclusion, our findings demonstrate that the computer-controlled olfactometer designed in this study can be used for a self-administered odor identification test.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00405-011-1593-zDOI Listing

Publication Analysis

Top Keywords

odor identification
36
identification test
28
computer-controlled olfactometer
16
test
13
self-administered odor
12
"sniffin' sticks"
12
odor
9
identification
9
olfactometer self-administered
8
identification tests
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!