Objectives: The purpose of this study was to compare lymphosonography (ie, contrast-enhanced ultrasound imaging [US] after interstitial injection of a US contrast agent) for the detection of sentinel lymph nodes (SLNs) in swine with naturally occurring melanoma tumors to lymphoscintigraphy using blue dye-guided surgical dissection as the reference standard. Also, we sought to determine if lymphosonography can be used to characterize SLNs.
Methods: Sixty-three swine with 104 melanomas were evaluated. Contrast-specific US was performed after peritumoral injection (1 mL dose) of Sonazoid (GE Healthcare, Oslo, Norway). Lymphoscintigraphy was performed after peritumoral injections of technetium Tc 99m sulfur colloid. Peritumoral injection of 1% Lymphazurin (Ben Venue Labs, Inc, Bedford, OH) was used to guide SLN resection. The accuracy of SLN detection with the two imaging modalities was compared using the McNemar test. The SLNs were qualitatively and quantitatively characterized as benign or malignant based on the lymphosonography results with histopathology and RNA analyses used as the reference standards.
Results: Blue dye-guided surgery identified 351 SLNs. Lymphosonography detected 293 SLNs and 11 false-positives, while lymphoscintigraphy detected 231 SLNs and 20 false-positives. The accuracy of SLN detection was 81.8% for lymphosonography, which was significantly higher than the 63.2% achieved with lymphoscintigraphy (P < .0001). The accuracy of lymphosonography for SLN characterization was 80%. When the size of the enhanced SLN was taken into consideration to characterize SLNs, the accuracy was 86%.
Conclusions: Lymphosonography is statistically better than lymphoscintigraphy for the detection of SLNs in this animal model. The ability to use lymphosonography as a means to characterize SLNs as benign or malignant is limited.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.7863/jum.2011.30.4.441 | DOI Listing |
Abdom Radiol (NY)
January 2025
University of Calgary, Calgary, Canada.
Objectives: Contrast enhanced ultrasound (CEUS) now joins the ranks of CT and MRI for noninvasive diagnosis of hepatocellular carcinoma (HCC). CEUS LI-RADS provides greater than 95% specificity for diagnosis within LR-5. Unlike CT/MRI, CEUS is nodule based.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Neurosurgery, University Hospital Tübingen, Tübingen, Germany.
To compare 1D (linear) tumor volume calculations and classification systems with 3D-segmented volumetric analysis (SVA), focusing specifically on their effectiveness in the evaluation and management of NF2-associated vestibular schwannomas (VS). VS were clinically followed every 6 months with cranial, thin-sliced (< 3 mm) MRI. We retrospectively reviewed and used T1-weighted post-contrast enhanced (gadolinium) images for both SVA and linear measurements.
View Article and Find Full Text PDFMethods Cell Biol
January 2025
Translational Radiomics, Luxembourg Institute of Health, Luxembourg City, Luxembourg; In-Vivo Imaging Platform, Luxembourg Institute of Health, Luxembourg City, Luxembourg.
During hypoxia, tissues are subjected to an inadequate oxygen supply, disrupting the balance needed to maintain normal function. This deficiency can occur due to reduced oxygen delivery caused by impaired blood flow or a decline in the blood's ability to carry oxygen. In tumors, hypoxia and vascularization play crucial roles, shaping their microenvironments and influencing cancer progression, response to treatment and metastatic potential.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Objective: This study aimed to introduce and evaluate a novel software-based system, BioTrace, designed for real-time monitoring of thermal ablation tissue damage during image-guided radiofrequency ablation for hepatocellular carcinoma (HCC).
Methods: BioTrace utilizes a proprietary algorithm to analyze the temporo-spatial behavior of thermal gas bubble activity during ablation, as seen in conventional B-mode ultrasound imaging. Its predictive accuracy was assessed by comparing the ablation zones it predicted with those annotated by radiologists using contrast-enhanced computed tomography (CECT) 24 hours post-treatment, considered the gold standard.
Oncol Lett
March 2025
Department of Imaging, The Affiliated Hospital of Beihua University, Jilin, Jilin 132011, P.R. China.
Contrast-enhanced ultrasonography (CEUS), a newly developed imaging technique, holds certain value in differentiating benign from malignant tumors. Additionally, serum tumor markers also exhibit significant clinical importance in the diagnosis and monitoring of malignant tumors. Reports have indicated abnormal expression of HER-2, CA153 and sE-cad in breast cancer.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!