A dual analyzer for real-time impedance and noise spectroscopy of nanoscale devices.

Rev Sci Instrum

School of Electrical Engineering, Korea University, Seoul 136-701, South Korea.

Published: March 2011

This paper introduces a simple portable dual analyzer which allows real-time ac-impedance measurements and noise spectroscopic analysis simultaneously, employing one or two data acquisition systems together with a low noise current-to-voltage preamplifier. The input signal composed of numerous selected frequencies of sinusoidal voltages with a dc bias was applied to a device under the test (DUT): single walled carbon nanotube field effect transistors (SWCNT-FETs). Each frequency component, ranging from 1 to 46.4 kHz, was successfully mapped to a Nyquist plot using the background of the electrical noise power spectrum. It is, thus, clearly demonstrated that this dual analyzer enables the real-time ac-impedance analysis and the frequency response of the carrier transport in the SWCNT-FETs as a DUT.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.3553208DOI Listing

Publication Analysis

Top Keywords

dual analyzer
12
real-time ac-impedance
8
analyzer real-time
4
real-time impedance
4
noise
4
impedance noise
4
noise spectroscopy
4
spectroscopy nanoscale
4
nanoscale devices
4
devices paper
4

Similar Publications

Bimodal In Situ Analyzer for Circular RNA in Extracellular Vesicles Combined with Machine Learning for Accurate Gastric Cancer Detection.

Adv Sci (Weinh)

January 2025

Department of Laboratory Medicine, Guangdong Provincial Key Laboratory of Precision Medical Diagnostics, Guangdong Engineering and Technology Research Center for Rapid Diagnostic Biosensors, Guangdong Provincial Key Laboratory of Single Cell Technology and Application, School of Laboratory Medicine and Biotechnology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, 510515, P. R. China.

Circular RNAs in extracellular vesicles (EV-circRNAs) are gaining recognition as potential biomarkers for the diagnosis of gastric cancer (GC). Most current research is focused on identifying new biomarkers and their functional significance in disease regulation. However, the practical application of EV-circRNAs in the early diagnosis of GC is yet to be thoroughly explored due to the low accuracy of EV-circRNAs analysis.

View Article and Find Full Text PDF

The incidence of type 2 diabetes mellitus (T2DM) complicated with osteoporosis (OP) (T2DM-OP) is growing. Dapagliflozin and metformin are commonly prescribed to manage glycemic levels in T2DM patients. We investigated the clinical efficacy of combining dapagliflozin with metformin in elderly patients with T2DM-OP.

View Article and Find Full Text PDF

This study investigated the implementation and impact of fifth-generation (5G) wireless millimeter wave (mmW) technology. 5G offers significant advancements over previous generations and supports additional frequency bands, including mmW, to enhance mobile broadband with ultra-reliable, low-latency communications, supporting a high volume of diverse communications. This technology is expected to enable billions of new connections in the Internet of Things (IoT), fostering innovations in various sectors including healthcare, manufacturing, and education.

View Article and Find Full Text PDF

Purpose: To evaluate the accuracy of toric intraocular lens (IOL) axis prediction between two preoperative measurement devices: the optical biometry (IOLMaster 500 or 700) and the dual Scheimpflug topography (Galilei G4).

Methods: Medical records of 64 eyes from 44 patients who underwent phacoemulsification and posterior chamber toric IOL (Zeiss AT TORBI 709M) implantation between July 2017 and January 2022 were reviewed. All patients underwent preoperative evaluation by optical biometry (IOLMaster 500 or IOLMaster 700) and Galilei G4.

View Article and Find Full Text PDF

Background/objectives: The aim of this study is to investigate the relationship between CRF (cardiorespiratory fitness) and body composition, specifically obesity indicators, in a sample of schoolchildren from the continental and Adriatic regions of the Republic of Croatia. Given that Croatia ranks among the leading countries in Europe in terms of obesity, it is believed that there is a need to combat this condition starting from school age. The usefulness of cardiorespiratory fitness (CRF) lies in the fact that it is one of the indicators of children's overall health and is considered a measure of general health status.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!