Objective: The loudness dependence of auditory evoked potentials (LDAEP) has been described as a measure of central serotonergic activity. Single-electrode estimation and dipole source analysis (DSA) are the most utilized methods for the estimation of LDAEP. To date, it is assumed that both methods are equally reliable. Nevertheless, according to our knowledge, the advantage of either method has not yet been shown directly. The aim of our study was to compare single-electrode estimation and dipole source analysis in the determination of the LDAEP.

Methods: Tones of five different intensities were presented binaurally to 10 healthy volunteers. Amplitudes of N1/P2 and LDAEP were determined at the central electrode site referenced to average and to linked mastoids and with DSA in the left and the right hemispheres. Scores were normalized (z-scores), compared, and correlated.

Results: Contrary to our expectations, we found a significant difference between scores obtained with single-electrode estimation and with DSA.

Conclusion: The difference may be caused by confounding activation of a frontal source in the single-electrode method. The single-electrode approach cannot be equated with DSA in the determination of the LDAEP. This should be considered when comparing the results of different LDAEP studies using only one of these methods.

Download full-text PDF

Source
http://dx.doi.org/10.1002/hup.1186DOI Listing

Publication Analysis

Top Keywords

single-electrode estimation
16
dipole source
12
source analysis
12
loudness dependence
8
dependence auditory
8
auditory evoked
8
evoked potentials
8
estimation dipole
8
single-electrode
6
estimation
5

Similar Publications

Effects of selective stimulation of apical electrodes on temporal pitch perception by cochlear implant recipients.

J Acoust Soc Am

September 2024

Aix Marseille Université, Centre National de la Recherche Scientifique, Centrale Méditerranée, Laboratoire de Mécanique et d'Acoustique, Centre National de la Recherche Scientifique, Aix Marseille Université, Marseille, 13453 Cedex 13, France.

Article Synopsis
  • * Three different stimulation methods were tested: using a single electrode at the very end of the implant, a mid-array electrode, and activating multiple electrodes at the apical end.
  • * Results showed that single-electrode stimulation did not enhance pitch perception compared to other methods, and there was no relationship between stimulation type and peripheral neural health.
View Article and Find Full Text PDF

Decades ago, neurosurgeons used electrical impedance measurements in the brain for coarse intraoperative tissue differentiation. Over time, these techniques were largely replaced by more refined imaging and electrophysiological localization. Today, advanced methods of diffusion tensor imaging (DTI) and finite element method (FEM) modeling may permit non-invasive, high-resolution intracerebral impedance prediction.

View Article and Find Full Text PDF
Article Synopsis
  • Spinal cord stimulation (SCS) shows promise for treating chronic pain and sensorimotor disorders, but the mechanisms and electrode placement effects on spinal recordings are not fully understood.
  • This study involved implanting electrode arrays in swine and used imaging techniques to analyze how electrode placement correlates with spinal anatomy and recording responses.
  • The findings revealed significant differences in the spatial relationship between electrode contacts and spinal nerve rootlets, indicating that electrode placement is critical for effective stimulation and recording in the spinal cord.
View Article and Find Full Text PDF

Quantitative measurement of the phasic (changes in several seconds) and tonic (changes in minutes to hours) level changes of neurotransmitters is an essential technique for understanding brain functions and brain diseases regulated by the neurotransmitters. However, monitoring phasic and tonic levels of multiple neurotransmitters is still a challenging technology. Microdialysis can measure the tonic levels of multiple neurotransmitters simultaneously but has a low temporal resolution (minute) to analyze precisely.

View Article and Find Full Text PDF

Background And Objective: Mental workload (MWL) is a relevant construct involved in all cognitively demanding activities, and its assessment is an important goal in many research fields. This paper aims at evaluating the reproducibility and sensitivity of MWL assessment from EEG signals considering the effects of different electrode configurations and pre-processing pipelines (PPPs).

Methods: Thirteen young healthy adults were enrolled and were asked to perform 45 min of Simon's task to elicit a cognitive demand.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!