Nurses are taught to place patients on their left-side postcolonoscopy to facilitate passing of flatus and relief of bloating, but there was no research evidence found to substantiate the use of that position. This study's purpose was to determine which position (left lateral, right lateral, or supine) was the most effective to encourage passing the insufflated room air and provide patient comfort after a colonoscopy. Sequential selection was used to assign one of three positions (168-174 patients per position) to 512 postcolonoscopy patients. Immediately following the procedure, the nurse placed the patient in the selected position. The patient's position, pain, bloating, vital signs, and passage of flatus were assessed every 15 minutes. A numerical rating scale of 1-10 was used to assess abdominal pain and bloating. Significant differences indicate that after colonoscopy, left lateral was the optimal position for facilitating passage of flatus and relieving bloating. The patients who were placed on their left side passed air more quickly than the patients in the other positions. The data show that after 30 minutes, most patients, regardless of which position they were in, passed the insufflated room air and were comfortable.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/SGA.0b013e31820f9ac3 | DOI Listing |
Sci Rep
January 2025
Division of Cardiology, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 50200, Thailand.
Pocket hematoma is a common and serious complication following cardiac implantable electronic device (CIED) implantation, contributing to significant morbidity and mortality. This study aimed to evaluate the efficacy of a novel pocket compression device in reducing pocket hematoma occurrence. We enrolled 242 patients undergoing CIED implantation, randomly assigning them to receive either the novel compression vest with a pressure cuff or conventional sandbag compression.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples "Federico II", 80131 Naples, Italy.
The anatomy of the sciatic nerve allows it to be blocked at different levels using various anesthetic approaches. However, for several reasons, performing these approaches may be challenging or disadvantageous in specific categories of patients, particularly in obese patients. The objective of this brief technical report is to describe a new technical approach to sciatic nerve block, designed to simplify the procedure for certain categories of patients and less experienced practitioners.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, 16126 Genova, Italy.
: A tracheostomy is a frequently performed surgical intervention in intensive care units (ICUs) for patients requiring prolonged mechanical ventilation. This procedure can offer significant benefits, including reduced sedation requirements, improved patient comfort, and enhanced airway management. However, it is also associated with various risks, and the absence of standardized clinical guidelines complicates its implementation.
View Article and Find Full Text PDFChildren (Basel)
January 2025
Pediatric Research Center, New Children's Hospital, University of Helsinki, Helsinki University Hospital, 00290 Helsinki, Finland.
Background: Recombinant growth hormone (rhGH) has been used since 1985 to treat growth hormone (GH)-induced short stature, typically associated with transient adverse events. However, lipoatrophy, characterized by irreversible damage to subcutaneous fat, was first reported in 1999 and linked to antibody formation. In 2021, localized lipoatrophy was observed in 14.
View Article and Find Full Text PDFBiomedicines
December 2024
DMG Dental-Material Gesellschaft mbH, 22547 Hamburg, Germany.
: Diphenyl (2,4,6-trimethylbenzoyl) phosphine oxide (TPO) is widely used in the dental industry as a photoinitiator for resin-based materials, while its use may be further limited given its toxicological risks. The aim of this study was, therefore, to analyze the residual TPO content of 3D-printed resin-based dental splint materials. : Six resin-based splint materials were analyzed: LuxaPrint Ortho Plus (DMG), FREEPRINT splint 2.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!