Objective: To investigate the failure of 15 dental implants (Paragon/Zimmer) in relation to their surface quality.

Materials And Methods: The study comprised of 15 dental implants (7 mm D Advent Implant, 3.9 mm D apex design implant), which were followed from surgery to completion of prosthetic restorations. The implants were placed during a 6-year period from 2003-2009 in non-smoking patients (male; 7, females; 5). There were eight upper and seven lower implants. Surface characterization after immersion in SBF of these failed implants was investigated using SEM and EDS compared to that of an unused implant of the same brand.

Results: Results revealed that, following immersion in SBF, the implant surfaces showed new components like Ca(+), Na(+) and Cl(-), but in trace quantities.

Conclusions: After SEM observation and EDS analysis, it was concluded that the apatite layer formation could not be verified.

Download full-text PDF

Source
http://dx.doi.org/10.3109/00016357.2011.569507DOI Listing

Publication Analysis

Top Keywords

dental implants
12
surface characterization
8
immersion sbf
8
implants
6
characterization analysis
4
analysis failed
4
failed dental
4
implants scanning
4
scanning electron
4
electron microscopy
4

Similar Publications

Background: Dental implantation of bone reconstructions in oncologic situations improves patients' orofacial function and quality of life. There are currently no recommendations on the timing of implantation.

Methods: This systematic review with meta-analysis aimed to compare primary and secondary dental implantation of free bone flaps in reconstructions for malignant tumors of the oral cavity.

View Article and Find Full Text PDF

Background: The selection guideline for the implant-supported bar connectors (ISBC) of hybrid denture is lacking. This study investigated the maximum von Mises stress (vMS), stress distribution, and displacement of various geometric ISBC in mandibular hybrid dentures, as well as the maximum principal stress (σmax) in the acrylic resin part, through finite element analysis.

Methods: Four different geometric cross-sectional patterns for mandibular ISBC-L, Y, I, and Square-of equal volume, based on the "All-on-4" concept, were created.

View Article and Find Full Text PDF

Background: Determining the distal cantilever length in All-on-Four (All-on-4) implant-supported prostheses is a major factor in the long-term success of these prostheses. The difference in mechanical properties of materials used in the fabrication of these prostheses, such as polyether ether ketone (PEEK), may have an impact on the determination of the cantilever length that best distributes stress.

Aim: To study the distribution of stress in All-on-4 mandibular prostheses in the bone, implants, and framework according to difference cantilever length in PEEK prosthetic framework using three-dimensional finite element analysis.

View Article and Find Full Text PDF

Digital planning and decision making for severe congenital oligodontia with Angle class-III malocclusion - Case series.

J Craniomaxillofac Surg

December 2024

Department of Oral and Maxillofacial Surgery, Rambam Health Care Campus, Haifa, Israel; Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel; Department of Oral and Maxillofacial rehabilitation, Rambam Health Care Campus, Haifa, Israel.

As maxillofacial surgery becomes increasingly digitized and the transformative impact of pre-surgical scanning and computer simulation is recognized, this clinical paper presents an algorithm for the selection of interventions in severe congenital oligodontia with Angle class-III malocclusion (OCIII) utilizing such technologies. A complex, multifactorial condition with varying degrees of craniofacial involvement, OCIII is associated with edentulous facial appearance, mandibular prognathism and deep underbite, as well as malocclusion. Our methodology involves the integration of CBCT imaging, intra- and extra- oral scanning, and 3D planning with the assessment of bone volume, number of missing teeth, skeletal discrepancies, and patient compliance in the selection of suitable treatments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!