A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a sandwich enzyme linked immunosorbent assay (ELISA) for the quantification of iduronate-2-sulfate sulfatase. | LitMetric

Iduronate-2-sulfate sulfatase (IDS; EC 3.1.6.13) is an enzyme that belongs to human sulfatases. IDS deficiency causes the Hunter syndrome or mucopolysaccharidosis type II (MPS II; OMIM 309900). We have been developing an expression system for human recombinant IDS (hrIDS) in Pichia pastoris, therefore a method was required for its detection during production and purification processes, which could be used also to measure the enzyme in human fluids. In this study, an immunoquantification assay for human and recombinant IDS was developed with the combination of two antibodies. Rabbit IgG and chicken IgY were used as IDS capture and detection antibodies, respectively. Chicken IgY antibodies were developed against specific amino acid sequences present in IDS but absent in other human sulfatases. hrIDS produced in P. pastoris, commercial hrIDS, and normal human plasma samples were used as antigens and immunoquantification results were compared to enzyme activity. The technique was linear over the range 8 to 500 ng mL(-1) using commercial hrIDS. The concentration range detected for IDS in normal human plasma was 14.43 to 287.88 ng mL(-1). The hrIDS was detected in P. pastoris cultures even when the enzyme was inactive, which is convenient for monitoring the production of recombinant proteins. These results show that chicken site-specific antibodies provide a good alternative, as a substitute of monoclonal antibodies, for the detection of human proteins. This is the first report on the development of an ELISA system to detect and quantify IDS with IgY antibodies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jim.2011.03.004DOI Listing

Publication Analysis

Top Keywords

iduronate-2-sulfate sulfatase
8
ids
8
human
8
human sulfatases
8
human recombinant
8
recombinant ids
8
chicken igy
8
igy antibodies
8
commercial hrids
8
normal human
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!