Conventionally used vascular grafts such as polyester (Dacron) or expanded polytetrafluoroethylene perform inadequately as small-diameter vascular bypass grafts (SDBGs). SDBGs, which can maintain long-term patency and those that could potentially evolve with the somatic growth, are highly desirable in vascular surgery and thus research into tissue-engineered blood vessels (TEBVs) is of keen interest. A TEBV was developed by seeding endothelial cells onto a collagen matrix that was cross-linked and contracted by smooth muscle cells (SMCs). A polyester graft served as a scaffold. Recovery studies (12 TEBVs and seven controls) were carried out to assess in vivo endothelialization and long-term patency of TEBVs. Hemodynamic observations indicated para-anastomotic turbulences and high shear stress at anastomosis. Recovery studies demonstrated confluent endothelialization, thrombus-free surfaces, and patent TEBVs in all cases. Graft incorporation and neovascularization of the scaffold occurred in both hybrid and control grafts. However, thickened neointima formation occurred in TEBV grafts, which was most likely caused by the rigidity of polyester scaffold. Significant perigraft inflammatory changes could be observed in both TEBVs and control grafts at 1, 4, and 8 weeks. In conclusion, the TEBVs demonstrated satisfactory performance as an infra-renal-aortic graft in a porcine model. The TEBV serves as a promising model and facilitates the development of a TEBV in a clinical setting, potentially with human stem cells and with more biocompatible, biodegradable scaffolds that are mechanically more compliant with natural vessels.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bab.8DOI Listing

Publication Analysis

Top Keywords

small-diameter vascular
8
vascular bypass
8
long-term patency
8
recovery studies
8
control grafts
8
tebvs
6
grafts
5
vivo study
4
study model
4
model tissue-engineered
4

Similar Publications

Microsurgical reconstruction constitutes a fundamental part of plastic and reconstructive surgery. It demands high dexterity and intricate technical skills. Its steep learning curve benefits from thorough training throughout residency, where using realistic simulation models in the appropriate sequence of complexity progression is essential in ensuring patient safety prior to progressing to a clinical setting.

View Article and Find Full Text PDF

Chitosan is generally considered to be a procoagulant effect, which may cause adverse phenomena such as blood clotting when used in small-diameter vascular grafts. However, it also shows good biocompatibility and anti-inflammatory properties, which can facilitate vascular reconstruction. Therefore, it is significant to transition the effect of chitosan from coagulation promotion to antiplatelet while still harnessing its bioactivity.

View Article and Find Full Text PDF

Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment.

Tissue Eng Regen Med

January 2025

College of Materials Science and Engineering, Hunan University, Changsha, 410072, People's Republic of China.

Background: Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.

Methods: A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring.

View Article and Find Full Text PDF

Rapid Preparation of Collagen/Red Blood Cell Membrane Tubes for Stenosis-Free Vascular Regeneration.

ACS Nano

January 2025

Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Road, Nanshan District, Shenzhen, Guangdong 518055, PR China.

Extracellular matrix (ECM)-based small-diameter vascular grafts (SDVGs, inner diameter (ID) < 6 mm) hold great promise for clinical applications. However, existing ECM-based SDVGs suffer from limited donor availability, complex purification, high cost, and insufficient mechanical properties. SDVGs with ECM-like structure and function, and good mechanical properties were rapidly prepared by optimizing common materials and preparation, which can improve their clinical prospects.

View Article and Find Full Text PDF

One-year patency of a novel biorestorative polymeric coronary artery bypass conduit.

Interdiscip Cardiovasc Thorac Surg

December 2024

Cardiac Surgery Department, Sanatorio Italiano, Asunción, Paraguay.

Coronary artery bypass graft (CABG) surgery remains the gold standard in the treatment of complex coronary artery disease. Saphenous vein grafts (SVG) are commonly used for the non-left anterior descending artery. However, SVG failure rates in CABG surgery have been reported to be as high as 30% at 1 year and ∼50% at 10 years.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!