A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Closed-loop seizure control with very high frequency electrical stimulation at seizure onset in the GAERS model of absence epilepsy. | LitMetric

A closed-loop system for the automated detection and control of epileptic seizures was created and tested in three Genetic Absence Epilepsy Rats from Strasbourg (GAERS) rats. In this preliminary study, a set of four EEG features were used to detect seizures and three different electrical stimulation strategies (standard (130 Hz), very high (500 Hz) and ultra high (1000 Hz)) were delivered to terminate seizures. Seizure durations were significantly shorter with all three stimulation strategies when compared to non-stimulated (control) seizures. We used mean seizure duration of epileptiform discharges persisting beyond the end of electrical stimulation as a measure of stimulus efficacy. When compared to the duration of seizures stimulated in the standard approach (7.0 s ± 10.1), both very high and ultra high frequency stimulation strategies were more effective at shortening seizure durations (1.3 ± 2.2 s and 3.5 ± 6.4 s respectively). Further studies are warranted to further understand the mechanisms by which this therapeutic effect may be conveyed, and which of the novel aspects of the very high and ultra high frequency stimulation strategies may have contributed to the improvement in seizure abatement performance when compared to standard electrical stimulation approaches.

Download full-text PDF

Source
http://dx.doi.org/10.1142/S0129065711002717DOI Listing

Publication Analysis

Top Keywords

electrical stimulation
16
stimulation strategies
16
high frequency
12
ultra high
12
absence epilepsy
8
seizures seizure
8
seizure durations
8
high ultra
8
frequency stimulation
8
high
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!