A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Toward noninvasive blood pressure assessment in arteries by using ultrasound. | LitMetric

Toward noninvasive blood pressure assessment in arteries by using ultrasound.

Ultrasound Med Biol

Section Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.

Published: May 2011

A new method has been developed to measure local pressure waveforms in large arteries by using ultrasound. The method is based on a simultaneous estimation of distension waveforms and velocity profiles from a single noninvasive perpendicular ultrasound B-mode measurement. Velocity vectors were measured by applying a cross-correlation based technique to ultrasound radio-frequency (RF) data. From the ratio between changes in flow and changes in cross-sectional area of the vessel, the local pulse wave velocity (PWV) was estimated. This PWV value was used to convert the distension waveforms into pressure waveforms. The method was validated in a phantom set-up. Physiologically relevant pulsating flows were considered, employing a fluid which mimics both the acoustic and rheologic properties of blood. A linear array probe attached to a commercially available ultrasound scanner was positioned parallel to the vessel wall. Since no steering was used, the beam was perpendicular to the flow. The noninvasively estimated pressure waveforms showed a good agreement with the reference pressure waveforms. Pressure values were predicted with a precision of 0.2 kPa (1.5 mm Hg). An accurate beat to beat pressure estimation could be obtained, indicating that a noninvasive pressure assessment in large arteries by means of ultrasound is feasible.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2011.01.020DOI Listing

Publication Analysis

Top Keywords

pressure waveforms
16
arteries ultrasound
12
pressure
8
pressure assessment
8
ultrasound method
8
large arteries
8
distension waveforms
8
waveforms pressure
8
ultrasound
6
waveforms
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!