This article describes a method of converting an interim maxillary removable complete denture to an interim implant-supported fixed complete denture. The advantages of this method are that it provides the opportunity to evaluate the patient's function and esthetics, and helps the accurate transfer of the maxillomandibular relationship to the laboratory. Consequently, the fabrication of the definitive prostheses is accurate, and the final result is predictable.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1532-849X.2011.00704.x | DOI Listing |
Int J Implant Dent
January 2025
Lecturer at removable prosthodontic department, Faculty of dental medicine for Girls, Al-Azhar University, Cairo, Egypt.
BMC Oral Health
January 2025
Faculty of Dentistry, British University in Egypt (BUE), Shorouk, Egypt.
Purpose: This study aimed to compare different treatment modalities to correct ill-fitted maxillary complete denture either by the conventional relining method or by scanning the relining impression and digitally construct a new denture regarding patient satisfaction, denture retention, and adaptation.
Materials And Methods: Twelve edentulous patients suffering from loose maxillary complete dentures were selected, dentures' borders and fitting surfaces were prepared, and relining impressions were taken, the impressions were scanned and the STL files were used for CAD/CAM milling ( computer aided designing/ computer aided manufacturing) of new maxillary dentures (Group A), then the relining impression went through the conventional laboratory steps to fabricate (Group B) maxillary dentures. Both groups were evaluated regarding patient satisfaction by a specially designed questionnaire, retention values were measured by a digital force gauge at denture insertion appointment and two weeks later, geomagic software was used to evaluate dentures adaptation to oral tissues.
J Prosthodont
January 2025
Department of Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan.
Purpose: This study aims to evaluate the effectiveness of a case-based reasoning (CBR) system in predicting the design of definitive obturator prostheses for maxillectomy patients.
Materials And Methods: Data from 209 maxillectomy cases, including extraoral images of obturator prostheses and occlusal images of maxillectomy defects, were collected from Institute of Science Tokyo Hospital. These cases were organized into a structured database using Python's pandas library.
J Prosthet Dent
January 2025
Assistant Professor, Department of Prosthodontic, College of Dental Medicine, Rangsit University, Phatum Thani, Thailand. Electronic address:
Statement Of Problem: Comprehensive data are needed on the performance of chemically activated, chairside hard reline materials when used with computer-aided design and computer-aided manufacturing (CAD-CAM) milled polymethyl methacrylate (PMMA) denture bases and conventionally processed bases. This lack of data affects decisions regarding the chairside reline material to be used for improving the fit and retention of relined complete dentures.
Purpose: The purpose of this in vitro study was to evaluate and compare the shear bond strength (SBS) of 3 chemically activated, chairside hard reline materials on CAD-CAM milled and conventional heat-polymerized PMMA denture bases.
J Indian Prosthodont Soc
January 2025
Department of Prosthodontics, K M Shah Dental College and Hospital, Sumandeep Vidyapeeth, Vadodara, Gujarat, India.
Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).
Setting And Design: In vitro (in silico study) finite element analysis (FEA).
Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!