This article describes a method of converting an interim maxillary removable complete denture to an interim implant-supported fixed complete denture. The advantages of this method are that it provides the opportunity to evaluate the patient's function and esthetics, and helps the accurate transfer of the maxillomandibular relationship to the laboratory. Consequently, the fabrication of the definitive prostheses is accurate, and the final result is predictable.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1532-849X.2011.00704.xDOI Listing

Publication Analysis

Top Keywords

complete denture
16
converting interim
8
interim maxillary
8
maxillary removable
8
removable complete
8
denture interim
8
interim implant-supported
8
implant-supported fixed
8
fixed complete
8
simplifying prosthetic
4

Similar Publications

Article Synopsis
  • A clinical trial tested the effectiveness of adding nanogold particles to denture bases made of polymethyl methacrylate (PMMA) against standard acrylic bases, focusing on their impact on bacterial growth.
  • Twenty-two male patients with no teeth received either traditional acrylic dentures or those enhanced with nanogold, and microbial growth was measured over time around the implants.
  • Results showed that dentures with nanogold significantly reduced bacteria counts (Candida albicans, Escherichia coli, and Streptococcus mutans) at 2, 4, and 6 months compared to traditional dentures, suggesting a promising improvement in oral hygiene.
View Article and Find Full Text PDF

Purpose: This study aimed to compare different treatment modalities to correct ill-fitted maxillary complete denture either by the conventional relining method or by scanning the relining impression and digitally construct a new denture regarding patient satisfaction, denture retention, and adaptation.

Materials And Methods: Twelve edentulous patients suffering from loose maxillary complete dentures were selected, dentures' borders and fitting surfaces were prepared, and relining impressions were taken, the impressions were scanned and the STL files were used for CAD/CAM milling ( computer aided designing/ computer aided manufacturing) of new maxillary dentures (Group A), then the relining impression went through the conventional laboratory steps to fabricate (Group B) maxillary dentures. Both groups were evaluated regarding patient satisfaction by a specially designed questionnaire, retention values were measured by a digital force gauge at denture insertion appointment and two weeks later, geomagic software was used to evaluate dentures adaptation to oral tissues.

View Article and Find Full Text PDF

Automated design prediction for definitive obturator prostheses: A case-based reasoning study.

J Prosthodont

January 2025

Department of Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan.

Purpose: This study aims to evaluate the effectiveness of a case-based reasoning (CBR) system in predicting the design of definitive obturator prostheses for maxillectomy patients.

Materials And Methods: Data from 209 maxillectomy cases, including extraoral images of obturator prostheses and occlusal images of maxillectomy defects, were collected from Institute of Science Tokyo Hospital. These cases were organized into a structured database using Python's pandas library.

View Article and Find Full Text PDF

Statement Of Problem: Comprehensive data are needed on the performance of chemically activated, chairside hard reline materials when used with computer-aided design and computer-aided manufacturing (CAD-CAM) milled polymethyl methacrylate (PMMA) denture bases and conventionally processed bases. This lack of data affects decisions regarding the chairside reline material to be used for improving the fit and retention of relined complete dentures.

Purpose: The purpose of this in vitro study was to evaluate and compare the shear bond strength (SBS) of 3 chemically activated, chairside hard reline materials on CAD-CAM milled and conventional heat-polymerized PMMA denture bases.

View Article and Find Full Text PDF

Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).

Setting And Design: In vitro (in silico study) finite element analysis (FEA).

Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!