A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In vitro fertilization on a single-oocyte positioning system integrated with motile sperm selection and early embryo development. | LitMetric

In vitro fertilization (IVF) technology has been broadly applied to solve human infertility in recent years. However, the physical tools for IVF remain unchanged over several decades before microfluidic technology was introduced in this field. Here, we report a novel microdevice that integrates each step of IVF, including oocyte positioning, sperm screening, fertilization, medium replacement, and embryo culture. Oocytes can be singly positioned in a 4 × 4 array of octacolumn units. The four symmetrical straight channels, crossing at the oocyte positioning region, allowed efficient motile sperm selection and facilitated rapid medium replacement. The fertilization process and early embryonic development of the individual zygote was traced with microscopic recording and analyzed by in situ fluorescent staining. The murine sperm motility was increased from 60.8 ± 3.4% to 96.1 ± 1.9% through the screening channels. The embryo growth rate and blastocyst formation were similar between the routine Petri dish group and the microdevice group. The healthy blastocysts developed in the microdevice could be conveniently retrieved through a routine pipetting operation and used for further embryo transfer.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac103063gDOI Listing

Publication Analysis

Top Keywords

vitro fertilization
8
motile sperm
8
sperm selection
8
oocyte positioning
8
medium replacement
8
fertilization single-oocyte
4
single-oocyte positioning
4
positioning system
4
system integrated
4
integrated motile
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!