A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Polymers and drugs suitable for the development of a drug delivery drainage system in glaucoma surgery. | LitMetric

Implantation of a glaucoma drainage system is an appropriate therapeutic intervention in some glaucoma patients. However, one drawback with this approach is the fibrotic tissue response to the implant material, leading to reduced flow of aqueous liquid or complete blockage of the drainage system. As a basis for developing an aqueous shunt we report here investigations with poly(3-hydroxybutyrate) (P(3HB)) and poly(4-hydroxybutyrate) (P(4HB)) as polymer matrices and with paclitaxel (PTX) and triamcinolone acetonide (TA) as drugs that might, in combination, delay or prevent the process of fibrosis by reducing fibroblast activity. P(3HB) and P(4HB) were fabricated into test prototypes with 500 μm outer and 200 μm inner diameter and ∼1 cm length. The antiproliferative agent PTX and the anti-inflammatory agent TA were incorporated into the polymer matrices and were released by diffusion. In vitro cell assays demonstrated that the polymers have the potential to reduce fibroblast viability, while TA showed differential inhibition of Tenon fibroblasts, but not cornea keratocytes. Implantation of polymer disks and prototype devices into rabbit eyes confirmed the good biocompatibility of the materials. The combined use of a poly(hydroxybutyrate) polymer with PTX or TA has the potential to reduce the fibrosis associated with conventional glaucoma drainage systems.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.31826DOI Listing

Publication Analysis

Top Keywords

drainage system
12
glaucoma drainage
8
polymer matrices
8
potential reduce
8
polymers drugs
4
drugs suitable
4
suitable development
4
development drug
4
drug delivery
4
drainage
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!