A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of reference concentrations of strontium in urine by inductively coupled plasma atomic emission spectrometry. | LitMetric

Objective: The aim of this study was to establish reference concentrations of urinary strontium by inductively coupled plasma atomic emission spectrometry (ICP-AES).

Methods: For the determination of strontium, urine samples were collected from healthy Japanese (n=146; 115 males, 31 females; mean age, 33±9 years; age range, 18 to 58 years). The urine samples stored at or below -20°C were thawed with incubation at 40°C for 30 min and sediments were dissolved by vigorous shakings. Then, the samples were centrifuged at 3000 g for 5 min, and the supernatant was directly aspired into a P-5200-3600/1200 ICP-AES system from Hitachi Ltd., Tokyo, Japan.

Results: A steeper increase in the S/N ratio and a good effective linearity of the calibration line was obtained at 407.771 nm in the range of 0-300 μg/L strontium standard solution. Urine samples having the same background signal as that of 18 MΩ cm ultrapure blank water, a good correspondence of the single peak pattern of the spectra, accuracy and precision of spike recovery were also confirmed. Urinary strontium concentrations showed a log-normal distribution and a geometric mean concentration of 143.9 μg/L, with 5-95% confidential interval of 40.9-505.8 μg/L.

Conclusion: The results of this study will be useful as guidelines for the biological monitoring of strontium in normal subjects and in individuals therapeutically or environmentally exposed to strontium.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2723615PMC
http://dx.doi.org/10.1007/BF02898202DOI Listing

Publication Analysis

Top Keywords

urine samples
12
reference concentrations
8
strontium urine
8
inductively coupled
8
coupled plasma
8
plasma atomic
8
atomic emission
8
emission spectrometry
8
urinary strontium
8
strontium
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!