[Effect of surface roughness and titanium dioxide layers on commercially pure titanium on attachment of osteoblasts].

Hua Xi Kou Qiang Yi Xue Za Zhi

Dept. of Prosthodontics, College of Stomatology, Kunming Medical University, Kunming 650031, China.

Published: February 2011

Objective: To study the effects of surface roughness and titanium dioxide (TiO2) layers on commercially pure titanium (cp-Ti) substrates on attachment of osteoblasts in vitro.

Methods: 250 pure titanium slices were divided into five groups. Osteoblasts were cultured on five cp-Ti substrates of ground, which blasted with 108-130 microm (S1), 216-301 microm (S2), 356-411 microm (S3) TiO2 particles and titanium-sprayed plasma (TPS) surfaces, surfaces prepared by hand grinding with SiC paper to 600 grits served as control (S0). Surface average roughness and the TiO2 film structure was evaluated. For morphology and attachment measurement, osteoblasts were cultured for 1, 4, 12 and 24 h, evaluated by scanning electronic microscope (SEM) observation and MTr assay.

Results: Osteoblasts spread well on the titanium surfaces. Further more, osteoblasts spread more well on S3 surfaces. After 1 and 4 h culture, the number of cells on S3 surfaces was the highest (P < 0.05). The number of cells on S3 surfaces was the same (P > 0.05) as TPS surfaces and higher than other groups (P < 0.05) after 12 and 24 h. The number of cells of all experimental groups were higher than S0 surfaces after 4, 12 and 24 h (P < 0.05).

Conclusion: It was concluded that the coarse TiO2 particles blasted surface would optimize initial osteoblast responses.

Download full-text PDF

Source

Publication Analysis

Top Keywords

pure titanium
12
number cells
12
surface roughness
8
roughness titanium
8
titanium dioxide
8
layers commercially
8
commercially pure
8
cp-ti substrates
8
osteoblasts cultured
8
tio2 particles
8

Similar Publications

Biocompatible TA4 and TC4ELI with excellent mechanical properties and corrosion resistance via multiple ECAP.

Biomed Mater

December 2024

State Key Laboratory of Nuclear Physics and Technology, Department of Technical Physics, School of Physics, Peking University, Beijing 100871, People's Republic of China.

Titanium (Ti), characterized by its exceptional mechanical properties, commendable corrosion resistance and biocompatibility, has emerged as the principal functional materials for implants in biomedical and clinical applications. However, the Ti-6Al-4V (TC4ELI) alloy has cytotoxicity risks, whereas the strength of the existing industrially pure titanium TA4 is marginally inadequate and will significantly limit the scenarios of medical implants. Herein, we prepared ultrafine-grained industrial-grade pure titanium TA4 and titanium alloy TC4ELI via the equal channel angular pressing method, in which the TA4-1 sample has ultrahigh strength of 1.

View Article and Find Full Text PDF

Objectives: To evaluate the influence of different dental implant materials within the exomass on the image quality in cone-beam computed tomography (CBCT).

Material And Methods: Five pig jaws were scanned using four CBCT devices, first without any dental implants, followed by scans with three dental implants of the same material-pure titanium, titanium-zirconium alloy, and zirconium dioxide. Two fields of view (FOVs) were used for each device to position the implants in the exomass of a small FOV and within a large FOV.

View Article and Find Full Text PDF

The potential carcinogenicity of orthopaedic implants - a scoping review.

BMC Cancer

December 2024

Department of Orthopaedics and Traumatology, School of Clinical Medicine, Faculty of Medicine, The University of Hong Kong, Hong Kong, China.

Background: Every year, hundreds of thousands of patients receive an orthopaedic or dental implant containing metals such as cobalt, chromium and titanium. Since the European Chemicals Agency (2020) classified pure cobalt metal as a Category 1B carcinogen, manufacturers of products containing ≥ 0.1% of this metal must perform a risk assessment and justify that there are no viable alternatives.

View Article and Find Full Text PDF

Background: Scandium-47 is the therapeutic counterpart to the diagnostic radionuclides, Sc and Sc. Together, these form elementally matched theranostic nuclide pairs, but their incorporation into radiopharmaceuticals requires developing production techniques leading to radioscandium isotopes with high chemical and radionuclidic purity. Previous Sc production methods involved expensive, enriched titanium targets that require additional procedures for target recovery.

View Article and Find Full Text PDF

This study examines the specimen size-dependent deformation behavior of commercially pure titanium grade 4 (cp-Ti grade 4) sheets under tension, with strain paths between uniaxial tension (UT) and plane-strain tension and compares the results with cyclic bending under tension (CBT) data. Specimens of varying widths (11.7, 20, 60, 100, and 140 mm) were tested in both rolling (RD) and transverse (TD) directions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!