A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of an adjustable model breast for mammographic dosimetry assessment in Taiwanese women. | LitMetric

Development of an adjustable model breast for mammographic dosimetry assessment in Taiwanese women.

AJR Am J Roentgenol

Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd, Hsinchu 30013, Taiwan, Republic of China.

Published: April 2011

Objective: The currently used model breast for mammographic dosimetry assessment lacks the flexibility to change dimensions. The aim of this study was to develop an adjustable model breast for mammographic dosimetry assessment of Taiwanese women.

Materials And Methods: A retrospective review of 4226 craniocaudal (CC) views was conducted. The geometry of the model breast was defined as a semielliptical cylinder. Breast parameters, including compressed breast thickness, chest wall-to-nipple distance, compressed breast width, and percentage glandular content, were measured and analyzed. To validate the adjustable model breast, 44 mammograms were obtained. The expected values from the adjustable model breast were compared with the measured values.

Results: The average values of compressed breast thickness, chest wall-to-nipple distance, compressed breast width, and percentage glandular content of the women studied were 4.1 cm, 6.9 cm, 16.9 cm, and 54%, respectively. Variations of chest wall-to-nipple distance, compressed breast width, and percentage glandular content can be expressed as functions of compressed breast thickness, and the adjustable model breast developed was based on compressed breast thickness. The average area of the CC view obtained is a factor of 0.81 lower than that defined by the American College of Radiology protocol. For validation, the difference in average values between the expected and measured did not exceed 0.5 cm in breast dimensions and 6% in percentage glandular content.

Conclusion: Compressed breast thickness is useful for quantifying dimensions and percentage glandular content of a model breast. The adjustable model breast developed in this study can offer greater flexibility in the determination of breast dimensions for mammographic dosimetry assessment of Taiwanese women.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.09.3700DOI Listing

Publication Analysis

Top Keywords

model breast
36
compressed breast
32
adjustable model
24
breast
20
breast thickness
20
percentage glandular
20
mammographic dosimetry
16
dosimetry assessment
16
glandular content
16
breast mammographic
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!