Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The currently used model breast for mammographic dosimetry assessment lacks the flexibility to change dimensions. The aim of this study was to develop an adjustable model breast for mammographic dosimetry assessment of Taiwanese women.
Materials And Methods: A retrospective review of 4226 craniocaudal (CC) views was conducted. The geometry of the model breast was defined as a semielliptical cylinder. Breast parameters, including compressed breast thickness, chest wall-to-nipple distance, compressed breast width, and percentage glandular content, were measured and analyzed. To validate the adjustable model breast, 44 mammograms were obtained. The expected values from the adjustable model breast were compared with the measured values.
Results: The average values of compressed breast thickness, chest wall-to-nipple distance, compressed breast width, and percentage glandular content of the women studied were 4.1 cm, 6.9 cm, 16.9 cm, and 54%, respectively. Variations of chest wall-to-nipple distance, compressed breast width, and percentage glandular content can be expressed as functions of compressed breast thickness, and the adjustable model breast developed was based on compressed breast thickness. The average area of the CC view obtained is a factor of 0.81 lower than that defined by the American College of Radiology protocol. For validation, the difference in average values between the expected and measured did not exceed 0.5 cm in breast dimensions and 6% in percentage glandular content.
Conclusion: Compressed breast thickness is useful for quantifying dimensions and percentage glandular content of a model breast. The adjustable model breast developed in this study can offer greater flexibility in the determination of breast dimensions for mammographic dosimetry assessment of Taiwanese women.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2214/AJR.09.3700 | DOI Listing |