A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Characteristics and dimensions of the Schneiderian membrane: a radiographic analysis using cone beam computed tomography in patients referred for dental implant surgery in the posterior maxilla. | LitMetric

Objectives: To determine the dimensions of the Schneiderian membrane using limited cone beam computed tomography (CBCT) in individuals referred for dental implant surgery, and to determine factors influencing the mucosal thickness.

Material And Methods: The study included 143 consecutive patients referred for dental implant placement in the posterior maxilla. A total of 168 CBCT images were taken using a limited field of view of 4 × 4 cm, 6 × 6 cm, or 8 × 8 cm. Reformatted coronal CBCT slices were analyzed with regard to the thickness and characteristics of the Schneiderian membrane in nine standardized points of reference. Factors such as age, gender, or status of the remaining dentition that could influence the dimensions of the Schneiderian membrane were evaluated using univariate and multivariate linear regression models.

Results: The thickness of the Schneiderian membrane exhibited a wide range, with a minimum value of 0.16 mm and a maximum value of 34.61 mm. The highest mean values, ranging from 2.16 to 3.11 mm, were found for the mucosa located in the mid-sagittal regions of the maxillary sinus. The most frequent mucosal findings diagnosed were flat thickenings of the Schneiderian membrane (62 positive findings, 37%). For the multivariate linear regression model, only gender had a statistically significant influence on the mean overall and mid-sagittal thickness of the sinus mucosa.

Conclusion: There is great interindividual variability in the thickness of the Schneiderian membrane. Gender seems to be the most important parameter influencing mucosal thickness in asymptomatic patients. Future studies are needed to assess the therapeutic and prognostic consequences of mucosal alterations in the maxillary sinus.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1600-0501.2010.02140.xDOI Listing

Publication Analysis

Top Keywords

schneiderian membrane
28
dimensions schneiderian
12
referred dental
12
dental implant
12
cone beam
8
beam computed
8
computed tomography
8
patients referred
8
implant surgery
8
posterior maxilla
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!