A beat-to-beat variation in the electric wave propagation morphology in myocardium is referred to as cardiac alternans and it has been linked to the onset of life threatening arrhythmias and sudden cardiac death. Experimental studies have demonstrated that alternans can be annihilated by the feedback modulation of the basic pacing interval in a small piece of cardiac tissue. In this work, we study the capability of feedback control to suppress alternans both spatially and temporally in an extracted rabbit heart and in a cable of cardiac cells. This work demonstrates real-time control of cardiac alternans in an extracted rabbit heart and provides an analysis of the control methodology applied in the case of a one-dimensional (1D) cable of cardiac cells. The real-time system control is realized through feedback by proportional perturbation of the basic pacing cycle length (PCL). The measurements of the electric wave propagation are obtained by optical mapping of fluorescent dye from the surface of the heart and are fed into a custom-designed software that provides the control action signal that perturbs the basic pacing cycle length. In addition, a novel pacing protocol that avoids conduction block is applied. A numerical analysis, complementary to the experimental study is also carried out, by the ionic model of a 1D cable of cardiac cells under a self-referencing feedback protocol, which is identical to the one applied in the experimental study. Further, the amplitude of alternans linear parabolic PDE that is associated with the 1D ionic cardiac cell cable model under full state feedback control is analyzed. We provide an analysis of the amplitude of alternans parabolic PDE which admits a standard evolutionary form in a well defined functional space. Standard modal decomposition techniques are used in the analysis and the controller synthesis is carried out through pole-placement. State and output feedback controller realizations are developed and the important issue of measurement noise in the controller implementation is addressed. The analysis of stabilization of the amplitude of alternans PDE is in agreement with the experimental results and numerical results produced by the ionic 1D cable of cardiac cells model. Finally, a discussion is provided in light of these results in order to use control to suppress alternans in the human myocardium.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3059280PMC
http://dx.doi.org/10.1016/j.compchemeng.2007.10.019DOI Listing

Publication Analysis

Top Keywords

cable cardiac
16
cardiac cells
16
feedback control
12
cardiac alternans
12
basic pacing
12
amplitude alternans
12
cardiac
10
alternans
9
control
8
control cardiac
8

Similar Publications

Background & Aim: Sternotomy remains a commonly used technique to access the heart for cardiac surgery worldwide. To date, there is no clear consensus on the single superior sternal closure technique. Patient-specific factors such as osteoporosis, diabetes, old age, body habitus influence a surgeon's choice in this matter as do techniques commonly used during the training period and used in the current workplace.

View Article and Find Full Text PDF

7 days of L-citrulline supplementation does not improve running performance in the heat whilst in a hypohydrated state.

Eur J Appl Physiol

December 2024

National Centre for Sport and Exercise Medicine, School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK.

Purpose: 7 days L-citrulline supplementation has been reported to improve blood pressure, O kinetics, gastrointestinal (GI) perfusion and endurance cycling performance through increasing arterial blood flow. In situations where blood volume is compromised (e.g.

View Article and Find Full Text PDF

How to undertake and record a 12-lead electrocardiogram.

Nurs Stand

December 2024

Faculty of Science and Technology, Department of Natural Sciences, Middlesex University London, London, England.

Rationale And Key Points: A 12-lead electrocardiogram (ECG) is a painless procedure commonly undertaken in healthcare practice. An ECG machine uses cables or 'leads' attached with stick-on electrodes to specific parts of the body to create a series of ECG traces, which are then printed onto graph paper. This provides a recording of the cardiac electrical activity measured from different angles or perspectives.

View Article and Find Full Text PDF

Chiari Network: Cause of an Unusual Difficulty during Atrial Septal Defect Device Closure.

Heart Views

October 2024

Department of Cardiology, SKIMS, Srinagar, Jammu and Kashmir, India.

Article Synopsis
  • There was a specific issue encountered while trying to remove an atrial septal defect device during a medical procedure.
  • The problem arose because the delivery cable got stuck in a prominent Chiari network, making it difficult to unscrew and release the device.
  • The authors recommend using careful imaging techniques, like transesophageal guidance, before and during the procedure to help identify and handle this rare challenge.
View Article and Find Full Text PDF

Ultrastructure and cardiac impulse propagation: scaling up from microscopic to macroscopic conduction.

J Physiol

November 2024

UCLA Cardiac Arrhythmia Center and Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, California, USA.

The standard conception of cardiac conduction is based on the cable theory of nerve conduction, which treats cardiac tissue as a continuous syncytium described by the Hodgkin-Huxley equations. However, cardiac tissue is composed of discretized cells with microscopic and macroscopic heterogeneities and discontinuities, such as subcellular localizations of sodium channels and connexins. In addition to this, there are heterogeneities in the distribution of sympathetic and parasympathetic nerves, which powerfully regulate impulse propagation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!