Aims: Conventional mapping and catheter ablation of non-sustained focal atrial tachycardia (AT) can be challenging and time consuming. We examined the characteristics and clinical outcomes after catheter ablation of recurrent, sustained AT presenting as non-sustained tachycardia during electrophysiological studies (EPSs), using a non-contact mapping system.
Methods And Results: In 9 of 88 consecutive patients undergoing ablation of sustained right AT, the tachycardia was non-sustained during EPSs, precluding conventional mapping. We used a non-contact system to map and guide the catheter ablation of brief induced episodes of AT. Atrial tachycardia originated in the crista terminalis (CT) in three patients, tricuspid annulus (TA) in four, posterior right atrium (RA) in one, and mid cavo-tricuspid isthmus in one patient. A QS morphology of the earliest virtual unipolar electrogram was systematically found at the site of successful catheter ablation. The breakout sites were near the CT in six, TA in three, posterior RA in one and anterior RA in one patient. In two patients, two separate breakout sites were identified. All AT (i) were focal and (ii) propagated preferentially to the breakout site(s) before depolarizing the atria. A mean of 5 ± 2 applications of radiofrequency energy was delivered without complications. Procedural duration and fluoroscopic exposure with the non-contact mapping system were 44 and 12 min, respectively. Over a follow-up of 16 ± 11 months, eight of nine patients remained asymptomatic, while in one patient a 'novel' AT emerged during follow-up.
Conclusion: Catheter ablation of non-sustained AT, using a non-contact mapping system, was safe and eliminated sustained AT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/eur058 | DOI Listing |
Pacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Pacing Clin Electrophysiol
January 2025
Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin, USA.
Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Department of Cardiology, Yan'an Hospital Affiliated to Kunming Medical University, Kunming, Yunnan, P.R. China.
Objective: The Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Section of Laboratory for Animal Experiments, Institute of Medical Science, Medical Research Support Center, Nihon University, School of Medicine, Tokyo, Japan.
Background: Neither the actual in vivo tissue temperatures reached with a novel contact force sensing catheter with a mesh-shaped irrigation tip (TactiFlex SE, Abbott) nor the safety profile has been elucidated.
Methods: In a porcine model (n = 8), thermocouples were implanted epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava following a right thoracotomy. After chest closure, endocardial ablation was conducted near the thermocouples under fluoroscopic guidance.
J Cardiovasc Electrophysiol
January 2025
Sakakibara Kinen Byoin, Fuchu, Japan.
Introduction: Freedom from recurrences of atrial tachyarrhythmia (ATA) is suboptimal after pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (PsAF). This sub-analysis from the Cryo Global Registry sought to investigate predictors of ablation success after PVI using cryoballoon ablation (CBA) for PsAF.
Methods And Results: ATA recurrence was defined as ≥ 30 s recurrence of atrial fibrillation, atrial flutter or atrial tachycardia after a 90-day blanking period and through 12-months.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!