A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cranio-spinal irradiation with volumetric modulated arc therapy: a multi-institutional treatment experience. | LitMetric

Purpose: To report the treatment of cranio-spinal irradiation (CSI) with volumetric modulated arc therapy (RapidArc) in adults and a child.

Materials And Methods: Five patients from 5 institutions were treated with CSI using RapidArc technology. Patient age varied between 7 and 45 years. The lengths of the planning target volumes (PTV) and dose prescriptions ranged from 54.6 to 78.4 cm, and from 12 to 36 Gy, respectively. Different arc arrangements were used, with two or three isocentres, from two to six modulated arcs, for patient positioned either in prone (n=3) or supine position (n=2). Doses to PTV, organs at risk and non-target tissue are reported for each of the five patients. Data concerning imaging strategy and pre-treatment quality assurance are also reported.

Results: The mean conformity index CI(95%) was 1.05 ± 0.05 (range: 1.00, 1.13). Mean doses to the lenses, lungs, heart, and kidneys were, respectively, 7.6 ± 1.6, 6.6 ± 3.0, 5.7 ± 2.3, and 6.1 ± 2.1 Gy, keeping those value acceptably low. Mean non-target tissue dose was 21.0 ± 3.8% (5.6 ± 1.8 Gy, range: 3.0-8.1 Gy). All patients were successfully planned and treated with RapidArc.

Conclusions: RapidArc techniques achieved highly conformal treatment plans for 5 adults or paediatric patients. Beam-on time was short, and RapidArc plans were satisfactorily delivered to all presented patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2011.01.023DOI Listing

Publication Analysis

Top Keywords

cranio-spinal irradiation
8
volumetric modulated
8
modulated arc
8
arc therapy
8
non-target tissue
8
patients
5
irradiation volumetric
4
therapy multi-institutional
4
multi-institutional treatment
4
treatment experience
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!