Download full-text PDF

Source
http://dx.doi.org/10.1016/j.recesp.2010.11.002DOI Listing

Publication Analysis

Top Keywords

[device thrombosis
4
thrombosis percutaneous
4
percutaneous closure
4
closure patent
4
patent foramen
4
foramen ovale]
4
[device
1
percutaneous
1
closure
1
patent
1

Similar Publications

Percutaneous Coronary Intervention (PCI) is a treatment method that involves reopening narrowed arteries with a balloon catheter that delivers a cylindrical, mesh-shaped implant device to the site of the stenosis. Currently, by applying a coating to a bare metal stent (BMS) surface to improve biocompatibility, the main risks after PCI, such as restenosis and thrombosis, are reduced while maintaining the basic requirements for the mechanical behavior of the stent itself. In this work, for the first time, the development and optimization process of the spatial structure of the Co-Cr stent (L-605) with a graphene-based coating using cold-wall chemical vapor deposition (CW-CVD) to ensure uniform coverage of the implant was attempted.

View Article and Find Full Text PDF

Catheter-related thrombosis (CRT) is a frequent and potentially serious complication associated with the widespread use of intravascular devices such as central venous catheters, including peripherally inserted central catheters and implantable port systems, pacemakers or implantable cardioverter-defibrillators. Although CRT management has been informed by guidelines extrapolated from lower extremity deep vein thrombosis (DVT), unique challenges remain due to the distinct anatomical, pathophysiological, and clinical characteristics of upper extremity DVT. Risk factors for CRT are multifactorial, encompassing patient-related characteristics such as cancer, prior venous thromboembolism, and infection, as well as catheter-specific factors like device type, lumens, and insertion site.

View Article and Find Full Text PDF

: ST-segment elevation myocardial infarction (STEMI) remains a leading cause of mortality worldwide, primarily caused by acute thrombosis over atherosclerotic plaques. Simultaneous acute thrombosis in two coronary arteries is an exceptionally rare event. This report highlights a unique case of STEMI associated with cardiogenic shock due to dual coronary artery thrombosis and provides insights from a literature review on this rare condition.

View Article and Find Full Text PDF

This article aims to introduce a novel full-endoscopic anterior cervical discectomy and fusion (ACDF) procedure to treat cervical myelopathy. Adoption of endoscopic anterior cervical procedures has been lagging due to safety concerns and the necessity of placing an interbody cage. We have developed novel instrumentation and a modified percutaneous anterior cervical approach that allows a safe and reproducible full-endoscopic ACDF.

View Article and Find Full Text PDF

Traditional mouse models for deep vein thrombosis (DVT), frequently utilized in research focused on cancer-associated thrombosis (CAT), reliably induce thrombus formation by obstructing blood flow (BF) in the inferior vena cava (IVC), which does not occur in humans. Therefore, to develop a new DVT model for CAT studies, we implanted an ameroid constrictor (AC), a hygroscopic casein C-shape device, around the IVC and aorta of immunocompromised mice. We evaluated the thrombus 3 and 8 days post-AC implantation and compared it with the traditional model 2 days post-vena cava ligation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!