A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Disinfection of greywater effluent and regrowth potential of selected bacteria. | LitMetric

Disinfection of greywater effluent and regrowth potential of selected bacteria.

Water Sci Technol

Department of Environmental, Water & Agricultural Engineering, Faculty of Civil & Environmental Engineering, Technion - Israel Institute of Technology, Haifa 3200 Israel.

Published: July 2011

Chlorination and UV irradiation of RBC (rotating biological contactor)-treated light GW (greywater) was investigated. The ability of chlorine and UV to inactivate indictor bacteria (FC - Faecal Coliforms, HPC - Heterotrophic Plate Count) and specific pathogens (P.a. - Pseudomonas aeruginosa sp., S.a. - Staphylococcus aureus sp.), was assessed and their regrowth potential was examined. The RBC removed 88.5-99.9% of all four bacteria groups. Nevertheless, the treated GW had to be disinfected. Most of the chlorine was consumed during the first 0.5 h, while later its decay rate decreased significantly, leaving enough residual after 6 h to prevent regrowth and to further inactivate bacteria in the stored GW effluent. Under exposure to low UV doses (≤69 mJ/cm(2)) FC was the most resistant bacteria group, followed by HPC, P.a. and S.a. Exposure to higher doses (≤439 mJs/cm(2)) completely inactivated FC, P.a. and S.a., while no further HPC inactivation was observed. FC, P.a. and S.a. did not exhibit regrowth after exposure to all the UV doses applied (up to 6 h storage). HPC did not exhibit regrowth after exposure to low UV doses (19-69 mJ/cm2), while it presented statistically significant regrowth in un-disinfected effluent and after exposure to higher UV doses (147-439 mJ/cm(2)).

Download full-text PDF

Source
http://dx.doi.org/10.2166/wst.2011.272DOI Listing

Publication Analysis

Top Keywords

regrowth potential
8
effluent exposure
8
exposure low
8
low doses
8
exposure higher
8
higher doses
8
exhibit regrowth
8
regrowth exposure
8
regrowth
6
bacteria
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!