Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: NMK36 is a novel PET tracer containing a synthetic amino acid analogue anti-[(18)F]FACBC as the active ingredient, and is under development for the use of tumor diagnosis. A Phase I clinical study of NMK36 was conducted to evaluate its safety, biodistribution, and radiation dosimetry in healthy volunteers.
Methods: Six healthy volunteers (Japanese male) received a bolus injection of NMK36 (174.4-201.4 MBq) intravenously. The safety of NMK36 was evaluated by monitoring signs/symptoms, electrocardiography, recording vital signs, and laboratory examinations at baseline and several time points in 6 days after injection. A total of 11 whole-body PET-CT scans were acquired up to 4 h post-injection, and venous blood and urine samples were also collected for 6 and 24 h post-injection, respectively. Based on the results of the biodistribution study, absorbed radiation dose was estimated by the MIRD method.
Results: Although two adverse events occurred after the injection of NMK36, they were mild and disappeared without any specific treatment. NMK36 preferentially accumulated in the pancreas and liver early after injection, followed by rapid clearance from the pancreas. Persistent uptake was observed in the skeletal muscle. NMK36 showed low uptake in the brain, and its urinary excretion was limited (5.40 ± 1.43% of the injected dose at 24 h post-injection). The liver was the critical organ, with a mean absorbed dose of 40.6 μGy/MBq. The estimated effective dose of NMK36 was 13.8 μSv/MBq, which was similar to or lower than those of radiotracers approved for clinical use including [(18)F]FDG.
Conclusions: The findings of this study indicate that NMK36 is well tolerated. NMK36 has favorable characteristics for imaging brain and pelvic tumors, such as low brain uptake, slow urinary excretion, and high in vivo stability.