This study used a biodegradable composite containing genipin-cross-linked gelatin annexed with β-tricalcium phosphate ceramic particles (genipin-gelatin-tricalcium phosphate, GGT), developed in a previous study, as a nerve guide conduit. The aim of this study was to analyse the influence of a large-area irradiated aluminium-gallium-indium phosphide (AlGaInP) diode laser (660 nm) on the neural regeneration of the transected sciatic nerve after bridging the GGT nerve guide conduit in rats. The animals were divided into two groups: group 1 comprised sham-irradiated controls and group 2 rats underwent low-level laser (LLL) therapy. A compact multi-cluster laser system with 20 AlGaInP laser diodes (output power, 50mW) was applied transcutaneously to the injured peripheral nerve immediately after closing the wound, which was repeated daily for 5 min for 21 consecutive days. Eight weeks after implantation, walking track analysis showed a significantly higher sciatic function index (SFI) score (P<0.05) and better toe spreading development in the laser-treated group than in the sham-irradiated control group. For electrophysiological measurement, both the mean peak amplitude and nerve conduction velocity of compound muscle action potentials (CMAPs) were higher in the laser-treated group than in the sham-irradiated group. The two groups were found to be significantly different during the experimental period (P<0.005). Histomorphometric assessments revealed that the qualitative observation and quantitative analysis of the regenerated nerve tissue in the laser-treated group were superior to those of the sham-irradiated group. Thus, the motor functional, electrophysiologic and histomorphometric assessments demonstrate that LLL therapy can accelerate neural repair of the corresponding transected peripheral nerve after bridging the GGT nerve guide conduit in rats.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.injury.2011.02.005 | DOI Listing |
J Coll Physicians Surg Pak
January 2025
Department of Orthopaedics and Traumatology, Faculty of Medicine, Sakarya University, Sakarya, Turkiye.
Objective: To compare the postoperative analgesic effectiveness of ultrasound-guided lumbar erector spinae plane (LESP) block with lumbar plexus block (LPB) in patients operated for proximal femur fractures.
Study Design: A randomised controlled trial. Place and Duration of the Study: Sakarya Training and Research Hospital Operation Theatre, Sakarya, Turkiye, between January and June 2023.
Eur Arch Otorhinolaryngol
January 2025
Vrije Universiteit Brussel, Brussels Health Centre, Brussels, Belgium.
Purpose: Cochlear implants (CI) are the most successful bioprosthesis in medicine probably due to the tonotopic anatomy of the auditory pathway and of course the brain plasticity. Correct placement of the CI arrays, respecting the inner ear anatomy are therefore important. The ideal trajectory to insert a cochlear implant array is defined by an entrance through the round window membrane and continues as long as possible parallel to the basal turn of the cochlea.
View Article and Find Full Text PDFJ Hand Ther
January 2025
Saint Joseph, MI, USA. Electronic address:
Background: For patients who experience atypical neurogenic pain thought to be complex regional pain syndrome (CRPS) after Dupuytren's fasciectomy early recognition has been reported to improve outcomes. Furthermore, given the progressive nature of Dupuytren's, individuals with a history of CRPS have been "at risk" for further surgical intervention.
Purpose: To familiarize therapists with a Budapest criteria (BC) checklist for early diagnosis of CRPS, describe how tracking sudomotor/vasomotor signs alongside differences in skin temperature were used to monitor vasomotor instability and intervention effectiveness for a patient with atypical pain after fasciectomy and to detail management of the same patient with a CRPS history who had collagenase clostridium histolyticum (CCH) injection of her other hand without exacerbating CRPS.
Hand Surg Rehabil
January 2025
CHU de Nîmes, avenue du Pr Debré, 30000 Nîmes, France.
The purpose of this study was to evaluate the results of a novel retrograde ultrasound-guided A1 pulley release technique for the treatment of trigger thumb. We conducted a retrospective, single-center study of 42 patients who underwent ultrasound-guided A1 pulley release for clinically diagnosed trigger thumb between September 2022 and December 2023. All cases were graded according to the Green classification of trigger finger severity.
View Article and Find Full Text PDFHand Surg Rehabil
January 2025
Centre Hospitalier Régional Universitaire de Nîmes, Department of Orthopaedic Surgery, Nîmes, France.
Dynamic compression of the median nerve under the lacertus fibrosus at the elbow causes pain and weakness. It is a frequently overlooked pathology and a cause of failed recovery after carpal tunnel release. The purpose was to present a technical note on minimally invasive ultrasound-guided lacertus syndrome surgical treatment under WALANT.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!