A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A new application of scanning electrochemical microscopy for the label-free interrogation of antibody-antigen interactions. | LitMetric

AI Article Synopsis

  • The study explores the use of scanning electrochemical microscopy (SECM) as a label-free method for detecting biomolecular interactions, presenting a new alternative to fluorescence techniques.
  • Biotinylated polyethyleneimine was used to create a dotted array on screen-printed carbon electrodes, which were then modified with neutravidin and a biotinylated antibody for neuron-specific enolase (NSE), enabling specific antigen-antibody binding detection.
  • The SECM demonstrated clear current changes upon antigen binding, indicating specific interactions, with a calibration curve established for NSE concentration from 500 fg mL(-1) to 200 pg mL(-1), showing a logarithmic relationship without requiring substrate labeling.

Article Abstract

Within this work we present a 'proof of principle' study for the use of scanning electrochemical microscopy (SECM) to detect and image biomolecular interactions in a label-free assay as a potential alternative to current fluorescence techniques. Screen-printed carbon electrodes were used as the substrate for the deposition of a dotted array, where the dots consist of biotinylated polyethyleneimine. These were then further derivatised, first with neutravidin and then with a biotinylated antibody to the protein neuron specific enolase (NSE). SECM using a ferrocene carboxylic acid mediator showed clear differences between the array and the surrounding unmodified carbon. Imaging of the arrays before and following exposure to various concentrations of the antigen showed clear evidence for specific binding of the NSE antigen to the antibody derivatised dots. Non-specific binding was quantified. Control experiments with other proteins showed only non-specific binding across the whole of the substrate, thereby confirming that specific binding does occur between the antibody and antigen at the surface of the dots. Binding of the antigen was accompanied by a measured increase in current response, which may be explained in terms of protein electrostatic interaction and hydrophobic interactions to the mediator, thereby increasing the localised mediator flux. A calibration curve was obtained between 500 fg mL(-1) to 200 pg mL(-1) NSE which demonstrated a logarithmic relationship between the current change upon binding and antigen concentration without the need for any labelling of the substrate.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2011.01.033DOI Listing

Publication Analysis

Top Keywords

scanning electrochemical
8
electrochemical microscopy
8
specific binding
8
non-specific binding
8
binding antigen
8
binding
6
antigen
5
application scanning
4
microscopy label-free
4
label-free interrogation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!