Nanolaminates such as the M(n + 1)AX(n) (MAX) phases are a material class with ab initio derived elasticity tensors published for over 250 compounds. We have for the first time experimentally determined the full elasticity tensor of the archetype MAX phase, Ti(3)SiC(2), using polycrystalline samples and in situ neutron diffraction. The experimental elastic constants show extreme shear stiffness, with c(44) more than five times greater than expected for an isotropic material. Such shear stiffness is quite rare in hexagonal materials and strongly contradicts the predictions of all published MAX phase elastic constants derived from ab initio calculations. It is concluded that second order properties such as elastic moduli derived from ab initio calculations require careful experimental verification. The diffraction technique used currently provides the only method of verification for the elasticity tensor for the majority of new materials where single crystals are not available.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0953-8984/22/16/162202 | DOI Listing |
Graefes Arch Clin Exp Ophthalmol
January 2025
Department of Ophthalmology, School of Medicine, Renji Hospital, Shanghai Jiao Tong University, 160 Pujian Road, Shanghai, 200001, China.
Purpose: To evaluate the posterior scleral stiffness of different regions in high myopic eyes and to explore its associations with macular choroidal and peripapillary retinal nerve fiber layer (pRNFL) thickness and vasculature.
Methods: Thirty subjects with high myopic eyes and 30 subjects with low myopic eyes were included in this study. The elastic modulus of the macular and peripapillary sclera at the temporal, nasal, superior and inferior regions were determined via shear wave elastography (SWE).
Front Vet Sci
December 2024
Department of Anatomy, Faculty of Veterinary Medicine, Istanbul University-Cerrahpasa, Istanbul, Türkiye.
Introduction: This study aims to quantify the shear wave speed (SWS) and stiffness of the uterine cervix (close to the internal cervical ostium (IOC) which is the cranial portion of cervix and close to the external cervical ostium (EOC) which is the caudal portion of cervix), caruncular areas, and vulvar labia during the postpartum period in healthy Kivircik ewes by using shear-wave elastography. Power Doppler ultrasonography was performed to evaluate the color pixel percentage (CPP) of the caruncles.
Methods: The study included 13 healthy pregnant Kivircik ewes, which were randomly selected.
Ultrasound Med Biol
January 2025
Echosens, Paris, France.
Objective: Although FibroScan (FS), based on Vibration-Controlled Transient Elastography (VCTE), is a widely used non-invasive device for assessing liver fibrosis and steatosis, its current standard-VCTE examination remains timely and difficult on patients with obesity. The Guided-VCTE examination uses continuous shear waves to locate the liver by providing a real-time predictive indicator for shear wave propagation and uses shear wave maps averaging to increase the signal-to-noise ratio in difficult to assess patients. We aimed to evaluate the effectiveness of the new indicator, as well as compare examination times and success rates with both standard-VCTE and Guided-VCTE examinations.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
January 2025
Department of orthopedic surgery, Clinique du Sport, 36 Boulevard Saint-Marcel, 75005 Paris, France.
Background: Many techniques have been described for lateral ankle ligament reconstruction. Although the biomechanical properties of gracilis tendons are different from those of ligaments, the use of a gracilis tendon autograft is a popular option for anatomical reconstruction. Graft maturation and the biomechanical processes over time remain unclear.
View Article and Find Full Text PDFJ Gynecol Obstet Hum Reprod
January 2025
Nanomedicine Imaging and Therapeutics Laboratory, INSERM EA 4662, University of Franche-Comte, Besançon, France; CHU de Besançon, Service de Gynécologie-Obstétrique, Besançon, France.
Objectives: This study aimed to describe the biometrics and elasticity of the perineal body and the anal sphincter in the ninth month of pregnancy and explore their association with the risk of perineal tears during childbirth.
Methods: In this prospective observational study, pregnant women at 36-40 weeks of gestation were included. Using transperineal 2D-mode ultrasound and shear wave elastography (SWE), we measured the biometrics and stiffness of the perineal body (PB), external anal sphincter (EAS), internal anal sphincter (IAS), and anal mucosa (AM) at rest and during Valsalva maneuvers.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!