A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pseudocontinuous arterial spin labeling perfusion magnetic resonance imaging--a normative study of reproducibility in the human brain. | LitMetric

Pseudocontinuous arterial spin labeling (PCASL), a newly proposed perfusion magnetic resonance imaging (MRI) technique, has the potential of providing a better balance between labeling efficiency and signal-to-noise ratio than conventional ASL methods. The advantage will not be exploitable until adequate reproducibility can be achieved. In this study, we investigated the reproducibility of PCASL on twelve healthy volunteers by taking into account the inclusion of correction for coil sensitivity (CS) and labeling efficiency (α). Each subject underwent two identical sessions scheduled two weeks apart. For comparison, pulsed ASL (PASL) imaging was also conducted using the flow-sensitive alternating inversion recovery method. MR imaging was performed on a 3T whole body system using a 12-channel phased array for reception. Blood flow was quantified for gray matter and assessed globally as well as in the flow territories of the internal carotid arteries and posterior cerebral arteries. Experimental results showed that CS accounted for 35% and 60% of inter-session variability in PCASL and PASL, respectively. With CS correction alone, coefficient of variance (CV) remained larger with PCASL than PASL (p=0.02). CV was 12% with CS-corrected PASL and 11% with PCASL when CS and α were corrected for in conjunction. We concluded that CS correction is necessary for ASL imaging when using phased array receiver and that after CS correction, PCASL requires α correction to provide reproducibility comparable to PASL.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neuroimage.2011.02.080DOI Listing

Publication Analysis

Top Keywords

pseudocontinuous arterial
8
arterial spin
8
spin labeling
8
perfusion magnetic
8
magnetic resonance
8
labeling efficiency
8
phased array
8
pcasl pasl
8
pcasl
6
correction
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!