Tubular scaffolds (internal diameter approximately 3 mm and wall thickness approximately 0.8 mm) with a porosity of approximately 83% and an average pore size of 116 µm were prepared from flexible poly(trimethylene carbonate) (PTMC) polymer by dip-coating and particulate leaching methods. PTMC is a flexible and biocompatible polymer that crosslinks upon irradiation; porous network structures were obtained by irradiating the specimens in vacuum at 25 kGy before leaching soluble salt particles. To assess the suitability of these scaffolds in dynamic cell culturing for cardiovascular tissue engineering, the scaffolds were coated with a thin (0.1 to 0.2 mm) non-porous PTMC layer and its performance was evaluated in a closed pulsatile flow system (PFS). For this, the PFS was operated at physiological conditions at liquid flows of 1.56 ml/s with pressures varying from 80-120 mmHg at a frequency of 70 pulsations per minute. The mechanical properties of these coated porous PTMC scaffolds were not significantly different than non-coated scaffolds. Typical tensile strengths in the radial direction were 0.15 MPa, initial stiffness values were close to 1.4 MPa. Their creep resistance in cyclic deformation experiments was excellent. In the pulsatile flow setup, the distention rates of these flexible and elastic scaffolds were approximately 0.10% per mmHg, which is comparable to that of a porcine carotid artery (0.11% per mmHg). The compliance and stiffness index values were close to those of natural arteries.?In long-term deformation studies, where the scaffolds were subjected to physiological pulsatile pressures for one week, the morphology and mechanical properties of the PTMC scaffolds did not change. This suggests their suitability for application in a dynamic cell culture bioreactor.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5301/ijao.2011.6396 | DOI Listing |
Acta Neurochir (Wien)
January 2025
Division of Neurosurgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street , Boston, MA, 02215, USA.
Background: Variability in long-term endovascular treatment outcomes for intracranial aneurysms has prompted questions regarding the effects of these treatments on aneurysm hemodynamics. Endovascular techniques disrupt aneurysmal blood flow and shear, but their influence on intra-aneurysmal pressure remains unclear. A better understanding of aneurysm pressure effects may aid in predicting outcomes and guiding treatment decisions.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
Columbia University Irving Medical Center, New York, NY, USA.
Background: Age-related changes in the systemic and cerebral vasculature adversely affect brain health and may contribute to neurodegeneration. However, the relationship between markers of systemic (arterial stiffness) and cerebral (flow pulsatility) vascular aging with neurodegeneration remains unclear. This study aimed to evaluate the associations of arterial stiffness and flow pulsatiility with blood biomarkers of neurodegeneration.
View Article and Find Full Text PDFRespir Res
January 2025
Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi'an, 710032, China.
Background: Acute pulmonary embolism represents the third most prevalent cardiovascular pathology, following coronary heart disease and hypertension. Its untreated mortality rate is as high as 20-30%, which represents a significant threat to patient survival. In view of the current lack of real-time monitoring techniques for acute pulmonary embolism, this study primarily investigates the potential of the pulsatility electrical impedance tomography (EIT) technique for the detection and real-time monitoring of acute pulmonary embolism through the collection and imaging of the pulsatile signal of pulmonary blood flow.
View Article and Find Full Text PDFMedicina (Kaunas)
December 2024
Department of Neurosurgery, Chung Shan Medical University Hospital, Taichung City 402, Taiwan, China.
Traumatic direct type carotid cavernous fistula (CCF) is an acquired arteriovenous shunt between the carotid artery and the cavernous sinus post severe craniofacial trauma or iatrogenic injury. We reported a 46-year-old woman who had developed a traumatic direct type CCF after severe head trauma with a skull base fracture and brain contusion hemorrhage. The clinical manifestations of the patient included pulsatile exophthalmos, proptosis, bruits, chemosis, and a decline in consciousness.
View Article and Find Full Text PDFBioengineering (Basel)
November 2024
Department of Mechanics & Engineering, College of Architecture & Environment, Sichuan University, Chengdu 610065, China.
Patients with anomalous coronary artery origins (AOCA) exhibit a higher risk of atherosclerosis, where even minimal stenosis may lead to adverse cardiovascular events. However, the factors contributing to this heightened risk in AOCA patients remain unclear. This study aimed to investigate whether an AOCA patient is more prone to stenosis occurrence and its progression in view of hemodynamics.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!