Significant progress in the development of implantable ventricular assist devices using continuous-flow blood pumps has been made recently. However, a control method has not been established. The blood pressure in the inflow cannula (inlet pressure) is one of the candidates for performing an adequate control. This could also provide important information about ventricle sucking. However, no calibration method for an inlet pressure sensor exists. In this study, an automatic calibration algorithm of the inlet pressure sensor from the pressure waveform at the condition of ventricle sucking was proposed. The calibration algorithm was constructed based on the consideration that intrathoracic pressure could be substituted for atmospheric pressure because the lung is open to air. We assumed that the inlet pressure at the releasing point of the sucking would represent the intrathoracic pressure, because the atrial pressure would be low owing to the sucking condition. A special mock circulation system that can reproduce ventricle sucking was developed to validate the calibration algorithm. The calibration algorithm worked well with a maximum SD of 2.1 mmHg for 3-min measurement in the mock circulation system. While the deviation was slightly large for an elaborate calibration, it would still be useful as a primitive calibration. The influence of the respiratory change and other factors as well as the reliability of the calibration value should be investigated with an animal experiment as a next step.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10047-011-0556-xDOI Listing

Publication Analysis

Top Keywords

inlet pressure
20
calibration algorithm
16
pressure sensor
12
ventricle sucking
12
pressure
11
automatic calibration
8
ventricular assist
8
calibration
8
intrathoracic pressure
8
mock circulation
8

Similar Publications

Objective: The triply periodic minimal surface (TPMS) Gyroid porous scaffolds were built with identical porosity while varying pore sizes were used by fluid mechanics finite element analysis (FEA) to simulate the microenvironment. The effects of scaffolds with different pore sizes on cell adhesion, proliferation, and osteogenic differentiation were evaluated through calculating fluid velocity, wall shear stress, and permeability in the scaffolds.

Methods: Three types of gyroid porous scaffolds, with pore sizes of 400, 600 and 800 μm, were established by nTopology software.

View Article and Find Full Text PDF

Bone is one of the hardest tissues in the human body, but it can undergo microcracks under long-term and periodic mechanical loads. The Newton iterative method was used to calculate the steady state, and the effects of different inlet and outlet pressures, trabecular gap width and height, and microcrack's depth and width on the fluid shear stress (FSS) were studied, and the gradient of FSS inside the microcrack was analyzed. The results show that the pressure difference and trabecular gap heigh are positively correlated with the FSS (the linear correlation coefficients were 0.

View Article and Find Full Text PDF

A novel remote deep ultraviolet laser ablation inlet connected to a dual electrospray ionization-atmospheric pressure chemical ionization (rDUVLAESCI) source is presented. This system allows for the simultaneous and spatial acquisition of mass spectrometry (MS) data for organic molecules with diverse polarities and molecular weights. Deep 193 nm UV laser ablation was used to sample analytes from dried spots for molecular MS analysis precisely.

View Article and Find Full Text PDF

This study examines how heart rate (HR) affects hemodynamics in a South African infant with Coarctation of the Aorta. Computed tomography angiography segments aortic coarctation anatomy; Doppler echocardiography derives inlet flow waveforms. Simulations occur at 100, 120, and 160 beats per minute, representing reduced, resting, and elevated HR levels.

View Article and Find Full Text PDF

In this study, a series of experiments are done to analyze the effect of bluff body geometry on the NO reduction of a natural gas-air stratified swirl burner. The stratified burner of Cambridge University is chosen to study the mentioned geometrical effect, and the geometry modification of bluff body is used as a simple method for NO reduction, which can be easily applied to the systems using these burners, including gas turbines. The bluff body geometrical change to an annular bluff body is inspired by the fact that the areas in which the edge of the bluff body is in contact with the unburned flow have lower temperatures, which can drastically affect combustion parameters, especially emissions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!