The agreement of plasma biochemical values between a portable point-of-care analyzer and a veterinary diagnostic laboratory in wild caught loggerhead sea turtles (Caretta caretta) was tested. Banked plasma samples from presumptively healthy turtles collected for an on-going project that involves health assessments of sea turtles from the southeast coast of Florida were used for this study. Plasma biochemical analytes evaluated included albumin, aspartate aminotransferase, calcium, creatinine kinase, glucose, potassium, sodium, phosphorus, total protein, bile acids, and uric acid. Paired plasma samples were run in duplicates and compared between a point-of-care analyzer and a veterinary diagnostic laboratory (VDL). Overall, the precision was greater as measured within the point-of-care analyzer than within the VDL analyzer; however, agreement between the two testing methods was poor. Correlation (r(i)) between the two analyzers was high for many of the analytes; however, the small P-value and high relative error led to the conclusion that the two analyzers were not equivalent. In addition, a comparison was made between the biochemical values obtained at the time of collection and after storage in an ultralow freezer for up to 2.5 yr. Plasma samples analyzed at the VDL, performed on different models of the same machine, were significantly lower after storage than those acquired near the time of collection. This difference was most likely because of sample degradation that occurred during storage. Whereas, statistically significant differences were observed within and between the analyzers, many of these differences may not be clinically significant. Even though this study has a few limitations, including a technical malfunction and the use of two different diagnostic laboratories, biochemical values for the given population are reported when using both a portable system and a diagnostic laboratory. Based on the findings of this study, the authors believe that point-of-care analyzers can provide valuable adjunctive diagnostics, especially in field situations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1638/2009-0023.1 | DOI Listing |
Curr Oncol
December 2024
Institute for Basic Sciences, Faculty of Physiotherapy, University of Physical Education, 31-571 Krakow, Poland.
Background: Multiple myeloma, a malignancy of plasma cells, often involves the disruption of vitamin D metabolism. Vitamin D, acting through its receptor (VDR), affects transcription factors like FOXO and sirtuins, which regulate cellular processes. The impact of physical activity on these markers in multiple myeloma patients is unclear.
View Article and Find Full Text PDFClin Chim Acta
December 2024
Newborn Screening, Clinical Biochemistry and Clinical Pharmacy Laboratory, Meyer Children's Hospital IRCCS, 50139 Florence, Italy; Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, 50139 Florence, Italy. Electronic address:
Int Immunopharmacol
December 2024
School of Pharmacy, Nantong University, Nantong, Jiangsu, China. Electronic address:
Non-alcoholic steatohepatitis (NASH) is the most common cause of chronic liver diseases with its pathophysiological mechanism poorly understood. In this work, serological, histological, molecular biological, biochemical, and immunological methods were applied to explore the pathological significance and action of zinc finger protein 281 (ZFP281 in mouse, ZNF281 in human) and targeted strategies. We reported that ZFP281/ZNF281 abundance in hepatocytes was positively correlated with the progression of NASH.
View Article and Find Full Text PDFUrolithiasis
December 2024
Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, Japan.
The early stages of kidney crystal formation involve inflammation and hypoxia-induced cell injury; however, the role of the hypoxic response in kidney crystal formation remains unclear. This study investigated the effects of a prolyl hydroxylase domain inhibitor (roxadustat) on renal calcium oxalate (CaOx) crystal formation through in vitro and in vivo approaches. In the in vitro experiment, murine renal tubular cells (RTCs) were exposed to varying roxadustat concentrations and CaOx crystals.
View Article and Find Full Text PDFArch Gynecol Obstet
December 2024
Maternal and Fetal Medicine Unit, São José Local Health Unit, Centro Clínico Académico de Lisboa, Lisbon, Portugal.
Objective: This study aimed to investigate the association between maternal factors and first-trimester biophysical and biochemical markers with small for gestational age (SGA) neonates in twin pregnancies (TwPs).
Methods: Single-center retrospective cohort study of TwPs followed from January 2010 to December 2022 at a tertiary perinatal center, Portugal. Maternal and pregnancy characteristics, mean arterial pressure, pregnancy-associated plasma protein-A (PAPP-A), β-human chorionic gonadotropin (β-HCG), and uterine artery pulsatility index (UtA-PI) were analyzed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!