Background: Previous studies have compared the accuracy of spiral analysis in distinguishing essential tremor (ET) from PD. In this study, we have used this technique to distinguish cases of tremulous PD (TDPD) (N = 24) from tremulous parkinsonian subjects without evidence of dopaminergic deficit (N = 41).

Methods: All patients were characterized on clinical and (123)I-N-ω-fluoro-propyl-2ß-carbomethoxy-3ß-(4-iodophenyl) nortropane ([(123)I] FP-CIT) SPECT scan data, which were concordant in every case. All analyses were carried out by observers blinded to the clinical details and supplied with just the spiral drawings, from which tremor severity (TS), 3-turn spiral diameter (3TD), and spiral density (SD) were measured.

Results: The spirals drawn by TDPD cases had significantly smaller 3TD (P = 0.029) and greater SD (P = 0.0082) than those with normal FP-CIT scans. There was no significant difference in the TS between the two groups (P = 0.11). The sensitivity and specificity of TS were 62.5% and 65.0%, 3TD were 75% and 56.7%, and SD were 30.4% and 82.5%, respectively, in predicting the correct classification. Further analyses combining these factors into pairs, showed that the respective sensitivities and specificities of (1) TS × 3TD were 75.0% and 40.0%, (2) TS/SD were 56% and 70.0%, and (3) 3TD/SD were 87.0% and 40.0%.

Discussion: There are significant differences in the 3TD and SD of spirals drawn by tremulous patients with normal versus abnormal FP-CIT scans. Spiral analysis may have some clinical value in helping to distinguish tremulous parkinsonian patients with normal presynaptic dopaminergic imaging from tremulous PD patients, providing results similar to those reported for expert movement disorder neurologists using standardized videotaped examinations.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mds.23507DOI Listing

Publication Analysis

Top Keywords

spiral analysis
12
fp-cit spect
8
spect scan
8
tremulous parkinsonian
8
spirals drawn
8
fp-cit scans
8
tremulous patients
8
patients normal
8
spiral
6
tremulous
6

Similar Publications

To reduce the adverse effects of bran on whole wheat flour products. In this study, seven reconstituted whole wheat flours were prepared and used to determine the effects of microwave and steam treatment on bran. We aimed to understand the effect of modification treatment on the properties of reconstituted whole wheat flour and dough.

View Article and Find Full Text PDF

[Analysis of 41 cases of myocardial infarction in children with coronary artery lesion after Kawasaki disease].

Zhonghua Er Ke Za Zhi

January 2025

Pediatric Heart Center, Children's Hospital of Fudan University, National Children's Medical Center, Shanghai, 201102 China.

To analyze the clinical characteristics,diagnosis and treatment of pediatric myocardial infarction (MI) patients with coronary artery lesions (CAL) after Kawasaki disease (KD). Clinical data including baseline characteristics, KD and CAL information, clinical symptoms at MI onset, electrocardiogram (ECG) and imaging findings, MI treatment, and clinical outcomes of 41 MI patients with CAL after KD admitted to the Children's Hospital of Fudan University from January 2017 to August 2024 were analyzed retrospectively. (1) Demographic characteristics: a total of 41 patients were included (36 males and 5 females).

View Article and Find Full Text PDF

Background: Tremor in essential tremor and in tremor-dominant Parkinson's disease is assessed by subjective observations in patients undergoing focused ultrasound thalamotomy, a minimally invasive procedure intended to alleviate tremor in these patients.

Objective: To develop an objective tool for tremor analysis to be used before and after focused ultrasound thalamotomy treatment in the treated hand (contralateral to ablation) and non-treated (ipsilateral to ablation).

Methods: Using image processing and signal processing that utilized images of a Archimedes spiral drawing, we created a tool to analyze tremor.

View Article and Find Full Text PDF

Introduction: Assessing the severity of kinetic tremor is important in clinical and research settings. Archimedes spirals are often used to assess tremor severity. Rating tremor from spirals has been based solely on visual information.

View Article and Find Full Text PDF

A multi-band high-sensitivity microwave sensor for simultaneous detection of two dielectric materials.

Rev Sci Instrum

January 2025

The State Key Laboratory of Complex Electromagnetic Environment Effects on Electronic and Information System, Luoyang 471004, China.

A multi-band high-sensitivity microwave sensor is reported. The two resonance units are based on complementary square spiral resonators (CSSRs) and produce four measurement bands through parasitic resonances. The four frequency bands are 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!