Real-time outdoor concealed-object detection with passive millimeter wave imaging.

Opt Express

Division of Computer and Communication Engineering, Daegu University, Gyeongsan, Gyeongbuk 712-714, Korea 2SamsungThales, Yongin 449-885, Korea.

Published: January 2011

Millimeter wave imaging is finding rapid adoption in security applications such as the detection of objects concealed under clothing. A passive imaging system can be realized as a stand-off type sensor that can operate in open spaces, both indoors and outdoors. In this paper, we address real-time outdoor concealed-object detection and segmentation with a radiometric imaging system operating in the W-band. The imaging system is equipped with a dielectric lens and a receiver array operating at around 94 GHz. Images are analyzed by multilevel segmentation to identify a concealed object. Each level of segmentation comprises vector quantization, expectation-maximization, and Bayesian decision making to cluster pixels on the basis of a Gaussian mixture model. In addition, we describe a faster process that adopts only vector quantization for the first level segmentation. Experiments confirm that the proposed methods provide fast and reliable detection and segmentation for a moving human subject carrying a concealed gun.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.19.002530DOI Listing

Publication Analysis

Top Keywords

imaging system
12
real-time outdoor
8
outdoor concealed-object
8
concealed-object detection
8
millimeter wave
8
wave imaging
8
detection segmentation
8
level segmentation
8
vector quantization
8
imaging
5

Similar Publications

External delay and dispersion correction of automatically sampled arterial blood with dual flow rates.

Biomed Phys Eng Express

January 2025

Brain Health Imaging Centre, Centre for Addiction and Mental Health, B68-250 College St, Toronto, Ontario, M5T 1R8, CANADA.

Objective: Arterial sampling for PET imaging often involves continuously measuring the radiotracer activity concentration in blood using an automatic blood sampling system (ABSS). We proposed and validated an external delay and dispersion correction procedure needed when a change in flow rate occurs during data acquisition. We also measured the external dispersion constant of [11C]CURB, [18F]FDG, [18F]FEPPA, and [18F]SynVesT-1.

View Article and Find Full Text PDF

Objective: Epilepsy is a common neurological disease affecting nearly 1% of the global population, and temporal lobe epilepsy (TLE) is the most common type. Patients experience recurrent seizures and chronic cognitive deficits that can impact their quality of life, ability to work, and independence. These cognitive deficits often extend beyond the temporal lobe and are not well understood.

View Article and Find Full Text PDF

Objective: Spinal fusion is a commonly performed surgical procedure used to relieve pain, deformity, and instability of various spinal pathologies. Although there have been attempts to standardize spinal fusion assessment radiologically, there is currently no unified definition that also considers clinical symptomology. This review attempts to create a more holistic and standardized definition of spinal fusion.

View Article and Find Full Text PDF

Objectives: The development of valuable artificial intelligence (AI) tools to assist with ultrasound diagnosis depends on algorithms developed using high-quality data. This study aimed to test the intra- and interobserver agreement of a proposed image-quality scoring system to quantify the quality of gynecological transvaginal ultrasound (TVS) images, which could be used in clinical practice and AI tool development.

Methods: A proposed scoring system to quantify TVS image quality was created following a review of the literature.

View Article and Find Full Text PDF

Purpose: We aimed to determine whether implementation of clinical decision support (CDS) tool integrated into the electronic health record (EHR) of a multi-site academic medical center increased the proportion of patients with American Urological Association (AUA) "high risk" microscopic hematuria (MH) who receive guideline concordant evaluations.

Materials And Methods: We conducted a two-arm cluster randomized quality improvement project in which 202 ambulatory sites from a large health system were randomized to either have their physicians receive at time of test results an automated CDS alert for patients with 'high-risk' MH with associated recommendations for imaging and cystoscopy (intervention) or usual care (control). Primary outcome was met if a patient underwent both imaging and cystoscopy within 180 days from MH result.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!