Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: This study compared the biomechanical behaviors of 4 implants in osteoporosis by 3-dimensional finite element analyses.
Materials And Methods: Finite element models (FEM) of posterior mandible segments with a cylindrical threaded implant, an apical tapered implant, a neck tapered implant (NTI), and an apical expandable implant were created. Bone segments with normal and osteoporotic biomechanical properties were used. Forces of 100 and 30 N were applied along the implant in axial and buccolingual (BL) directions, respectively. Maximum equivalent stresses in the jaw bone and maximum displacement in the implant-abutment complex were evaluated.
Results: In osteoporosis, compared with the cylindrical threaded implant, maximum equivalent stress in cortical bones with the apical tapered implant decreased by 10.1% and 6.57% under axial and BL loads, respectively. With the NTI, those values decreased by 10.72% and 7.87%. With the apical expandable implant, those values decreased by 11.3% and 9.60%. In cancellous bones, the maximum equivalent stress with the NTI decreased by 3.56% under a BL load. Maximum displacement in the implant-abutment complex decreased by 17.1% and 9.41% with an apical tapered implant under axial and BL loads, respectively. With the NTI, those decreased by 21.8% and 17.4%. Values in normal bone indicated better stress distributions and less displacement than those in osteoporotic bone.
Conclusion: Stress distribution in the jaw bone and implant stability in osteoporotic bone were more sensitive to implant designs than those in normal bone. In osteoporotic bone, the expandable implant and the NTI showed better stress distribution, and tapered implants showed better stabilities.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.joms.2010.12.006 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!