A renewable flow cell integrating a microstructured pillar-array filter and a pneumatic microvalve was microfabricated to trap and release beads. A bead-based immunoassay using this device was also developed. This microfabricated device consists of a microfluidic channel connecting to a beads chamber in which the pillar-array filter is built. Underneath the filter, there is a pneumatic microvalve built across the chamber. Such a device can trap and release beads in the chamber by "closing" or "opening" the microvalve. On the basis of the pneumatic microvalve, the device can trap beads in the chamber before performing an assay and release the used beads after the assay. Therefore, this microfabricated device is suitable for "renewable surface analysis". A model analyte, 3,5,6-trichloropyridinol (TCP), was chosen to demonstrate the analytical performance of the device. The entire fluidic assay process, including beads trapping, immuno binding, beads washing, beads releasing, and chemiluminesence signal collection, could be completed in 10 min. The immunoassay of TCP using this microfabricated device showed a linear range of 0.20-70 ng/mL with a limit of detection of 0.080 ng/mL. The device was successfully used to detect TCP spiked in human plasma at the concentration range of 1.0-50 ng/mL, with an analytical recovery of 81-110%. The results demonstrated that this device can provide a rapid, sensitive, reusable, low-cost, and automatic tool for detecting various biomarkers in biological fluids.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac1032116 | DOI Listing |
Lab Chip
September 2024
Bioengineering Program, The University of Kansas, Lawrence, KS 66045, USA.
Microfluidic systems combine multiple processing steps and components to perform complex assays in an autonomous fashion. To enable the integration of several bio-analytical processing steps into a single system, valving is used as a component that directs fluids and controls introduction of sample and reagents. While elastomer polydimethylsiloxane has been the material of choice for valving, it does not scale well to accommodate disposable integrated systems where inexpensive and fast production is needed.
View Article and Find Full Text PDFLab Chip
September 2024
School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China.
This review summarizes programmable microfluidics, an advanced method for precise fluid control in microfluidic technology through microchannel design or liquid properties, referring to microvalves, micropumps, digital microfluidics, multiplexers, micromixers, slip-, and block-based configurations. Different microvalve types, including electrokinetic, hydraulic/pneumatic, pinch, phase-change and check valves, cater to diverse experimental needs. Programmable micropumps, such as passive and active micropumps, play a crucial role in achieving precise fluid control and automation.
View Article and Find Full Text PDFMicrosyst Nanoeng
August 2024
Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080 USA.
Neuroinflammation is characterized by the elevation of cytokines and adenosine triphosphate (ATP), which in turn activates microglia. These immunoregulatory molecules typically form gradients in vivo, which significantly influence microglial behaviors such as increasing calcium signaling, migration, phagocytosis, and cytokine secretion. Quantifying microglial calcium signaling in the context of inflammation holds the potential for developing precise therapeutic strategies for neurological diseases.
View Article and Find Full Text PDFSensors (Basel)
April 2024
Department of Precision Instrument, Tsinghua University, Beijing 100084, China.
This paper discusses a microfluidic system designed for surface plasmon resonance (SPR) sensing, incorporating integrated microvalves. This system is built from a layered structure of polydimethylsiloxane (PDMS) and polymethylmethacrylate (PMMA). The functionality of the microvalves is verified through a conductance method involving electrodes positioned at the microfluidic channels' inlets and outlets.
View Article and Find Full Text PDFRes Sq
December 2023
Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
Calcium dynamics significantly influence microglial cell immune responses, regulating activation, migration, phagocytosis, and cytokine release. Understanding microglial calcium signaling is vital for insights into central nervous system immune responses and their impact on neuroinflammation. We introduce a calcium monitoring micro-total analysis system (CAM-μTAS) for quantifying calcium dynamics in microglia (BV2 cells) within defined cytokine microenvironments.