We experienced a case in which a total arch replacement and an open stent implantation were performed for a distal aortic arch aneurysm using a newly developed stent graft (Ube CL-0201; Ube Medical, Tokyo, Japan). This novel stent graft is composed of a woven polyester graft and a nickel-titanium alloy stent, and has been under evaluation in clinical trials at four institutions in Japan, including our hospital, since 2008. The patient was weaned from the respirator on the day after surgery, and 9 months have passed since the surgery with no complications. A follow-up computed tomography scan showed that the stent part was sufficiently open, and no complications, such as an endoleak, have been observed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00595-010-4264-6 | DOI Listing |
J Clin Med
January 2025
Department of Vascular Surgery, University Hospital Zurich, 8091 Zurich, Switzerland.
: The parallel stent graft endovascular aortic repair (PGEVAR) technique is an off-the-shelf option used for elective complex abdominal aortic aneurysm repair with acceptable outcome results, as reported so far. The PGEVAR technique, using chimney or periscope parallel grafts, can also be used for patients with ruptured complex abdominal aortic aneurysms. However, only few data about the mid- to long-term outcomes are available.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité, 13353 Berlin, Germany.
The HeartMate 3 (HM3, Abbott) left ventricular assist device (LVAD) is the only commercially available option considered suitable for long-term circulatory support. External compression of the outflow graft causing obstruction (eOGO) is a serious adverse event affecting patients on long-term support. The obstruction occurs due to the accumulation of gelatinous substance between the bend relief and outflow graft.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Surgery, Kurume University School of Medicine, Fukuoka 830-0011, Japan.
Endovascular stent graft repair was developed to minimize the invasiveness of open surgery for thoracic and abdominal aortic diseases. This approach involves covering the diseased segment with a stented artificial graft. However, in thoracic endovascular aortic repair (TEVAR) for aortic arch diseases, special consideration is needed to preserve the aortic arch vessels.
View Article and Find Full Text PDFCan J Cardiol
January 2025
Cardiovascular department, Cardiology Research Institute, Tomsk National Research Medical Centre, Russian Academy of Sciences, Tomsk, Russian Federation.
Background: The aim of the study was to analyze the mid-term outcomes of the frozen elephant trunk (FET) procedure for chronic aortic dissection (СAD).
Methods: From March 2012 to December 2022, 123 FET procedures were performed in patients with acute and chronic aortic dissection as well as aortic aneurysm. Fifty-five patients with chronic aortic dissection (CAD) were eligible for study.
Scand J Surg
January 2025
Interdisciplinary Endoscopy Centre, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120 Heidelberg, Germany.
Background And Aims: The therapeutic management of fistulas presents significant challenges, often involving both conservative and surgical approaches. Despite these interventions, recurrence and postoperative mortality rates remain high. Endoscopic stent insertion into the fistula, along with the creation of a stent stoma, may offer a promising alternative for patients who fail surgical or conservative therapies.