Multiple groups have hypothesised that the use of scanning beams in proton therapy will reduce the neutron component of secondary radiation in comparison with conventional methods with a corresponding reduction in risks of radiation-induced cancers. Loma Linda University Medical Center (LLUMC) has had FDA marketing clearance for scanning beams since 1988 and an experimental scanning beam has been available at the LLUMC proton facility since 2001. The facility has a dedicated research room with a scanning beam and fast switching that allows its use during patient treatments. Dosimetric measurements and microdosimetric distributions for a scanned beam are presented and compared with beams produced with the conventional methods presently used in proton therapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncq513 | DOI Listing |
Background And Purpose: Radiation induced image changes (IC) on MRI have been observed after proton therapy for brain tumours. This study aims to create predictive models, with and without taking into account patient variation, based on dose, linear energy transfer (LET) and periventricular zone (PVZ) in a national cohort of patients with glioma treated with pencil beam scanning (PBS).
Materials And Methods: A cohort of 87 consecutive patients with oligodendroglioma or astrocytoma (WHO grade 2-4) treated with PBS from January 2019 to December 2021 was included.
Polymers (Basel)
December 2024
Department of Architectural Engineering, Gachon University, Seongnam-si 13120, Republic of Korea.
The absence of carbon fiber-reinforced rebar performance standards in Korea has limited its reliability. This study investigates the durability performance of carbon fiber-reinforced polymer rebar as an alternative to traditional steel reinforcement in concrete structures. Concrete beams reinforced with carbon fiber-reinforced polymer rebar were exposed to chloride environments for durations of 35 and 70 days and then subjected to bending tests to evaluate their durability.
View Article and Find Full Text PDFJ Prosthodont Res
January 2025
Department of Orthodontics, Osaka Dental University, Hirakata, Japan.
Purpose: To perform vertical bone augmentation on rat parietal bone by coating the inner surface of dense polytetrafluoroethylene (d-PTFE) domes with hydroxyapatite (HA) using Erbium Yttrium Aluminum Garnet (Er:YAG) pulsed laser deposition in a rat model.
Methods: The d-PTFE plate surface, α-tricalcium phosphate (α-TCP) coating, and HA coating were measured using scanning electron microscopy and X-ray diffraction to confirm the replacement of α-TCP with HA via high-pressure steam sterilization. The dome was glued to the center of the rat parietal bone and closed with periosteal and epithelial sutures.
Phys Med
January 2025
Department of Medical Physics, Apollo Proton Cancer Centre, 100 Feet Road Taramani, Chennai, Tamil Nadu, India. Electronic address:
Objectives: The purpose of this study was to investigate the fundamental properties of spot-scanning proton beams and compare them to Monte Carlo (MC) simulations, both with and without CT calibration, using spatially diverse combinations of materials.
Methods: A heterogeneous phantom was created by spatially distributing titanium, wax, and thermocol to generate six scenarios of heterogeneous combinations. Proton pencil beams ranging in energy from 100 to 226.
Sci Rep
January 2025
Ophthalmic Pathology Laboratory, L V Prasad Eye Institute, Kallam Anji Reddy Campus, 500034, Hyderabad, India.
To examine ultrastructural changes in the trabecular meshwork (TM) in patients with primary and secondary glaucoma using scanning electron microscopy (SEM). This was a qualitative descriptive hospital-based study on the ultrastructure of the TM. Pure TM samples were collected after microincisional trabeculectomy from 26 patients with primary or secondary glaucoma and 10 control samples from eye bank donor corneas.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!